PV1000a pellet burner
p
56/ 58
DK9401B1 www.pelltech.eu
PAR58
BASE FREQUENCY
Grid frequency
Hz
50
45
63
50
45
63
PAR60
FLUE GAS TYPE
Flue gas fan ON-OFF turning 0 OFF 2 ON
-
2
0
2
2
0
2
PAR61
DRAFT SET
Flue gas fan pre-set pressure set point
-Pa
8
0
250
8
0
250
PAR62
DRAFT ERROR
Draught error threshold value
+Pa
10
0
20
10
0
20
PAR63
DRAFT BASE
Draught sensor calibration value
%
110
50
150
110
50
150
PAR66
OXYGEN TYPE
Type of oxygene sensor:
0 no sensor;
1 4..20mA=0..25%;
2 4..20mA=0..20%
-
0
0
2
0
0
2
PAR67
OXYGEN SET
Oxygen level setpoint
%
6
4
14
6
4
14
PAR70
HEAT UP TIME
Initial heat up time for burners with ceramic burning
chamber
min
20
0
60
20
0
60
PAR71
HEAT UO POWER
Initial heat up power for burners with ceramic burning
chamber
kW
5
1
10
7
1
15
PAR72
HEAT UP TEMP.
Initial heat up temperature for burners with ceramic
burning chamber
-
50
25
90
50
25
90
PAR73
TEMP BASE
TEMP BASE
-
20
0
100
20
0
100
PAR99
BURNER TYPE
Selecting model of burner. Software of wrongly
selected model works incorrectly
-
700
20
1M
1M
20
1M
11 Annex 5 Table of languages
Language
ENG
English
SPA
Spanish
EST
Estonian
FIN
Finnish
FRA
France
GER
Germany
GRE
Greece
HRV
Croatian
LIT
Lithuanian
LAT
Latvian
NED
Dutch
POR
Portuguese
RUS
Russian
SLO
Slovenian
SRB
Serbian
SVK
Slovakian
SWE
Swedish