PV1000a pellet burner
p
55/ 58
DK9401B1 www.pelltech.eu
PAR22
PELLETS LIGHT
Determines how many grams of pellets feeder auger
transports to burning chamber with one full rotation
when PELLET LIGHT ie lighter than normal weight
pellets are selected
g/rot
150
120
250
150
120
250
PAR23
PELLETS HEAVY
Determines how many grams of pellets feeder auger
transports to burning chamber with one full rotation
when PELLET HEAVY ie heavier than normal weight
pellets are selected
g/rot
170
120
250
170
120
250
PAR24
LOADING FEED
Number of feeder auger rotations in LOADING state
rot
40
20
80
40
20
80
PAR25
LOADING 2 FEED
Number of feeder auger rotations in LOADING2 state
rot
5
1
15
5
1
15
PAR26
END BURN FEED
Number of feeder auger rotations in END BURN state
rot
70
40
120
80
20
120
PAR27
END BLOW TIME
Fan's END BLOW time after flame has disappeared
sec
2
1
15
2
1
15
PAR30
FAN 2
Secondary fan On//OFF control (not used in PV50b)
1/2
3
1
3
3
1
3
PAR31
FAN 2@200(250)
Secondary fan speed at 1.power level PV700(PV1000)
rps
13
5
80
16
5
40
PAR32
FAN 2@300(400)
Secondary fan speed at 2.power level PV700(PV1000)
rps
23
5
80
22
5
50
PAR33
FAN 2@400(550)
Secondary fan speed at 3.power level PV700(PV1000)
rps
32
5
80
30
5
55
PAR34
FAN 2@500(700)
Secondary fan speed at 4.power level PV700(PV1000)
rps
39
5
80
38
5
55
PAR35
FAN 2@600(850)
Secondary fan speed at 5.power level PV700(PV1000)
rps
41
5
80
42
5
55
PAR36
FAN 2@700(1000)
Secondary fan speed at 6.power level PV700(PV1000)
rps
43
5
80
46
5
55
PAR38
FAN 2 BASE
Changing amount of secondary fan base air with flue
gas fan speed setting in all power levels
%
100
65
140
100
65
140
PAR39
FAN 2 MIN
Secondary fan minimal speed
rps
7
5
20
7
5
20
PAR40
PHOTOCELL LEVEL
Flame sensor sensitivity. Higher number means that
flame is recognized when less light
%
90
50
100
90
50
100
PAR41
PRE-BURN TIME
Length of one PRE-BURN cycle state
sec
25
15
80
25
15
80
PAR42
PRE-BURN CYCLES
Number of PRE-BURN cycles. Total length of PRE-BURN
cycles is length of one cycle times number of cycles
X
6
2
10
6
2
10
PAR46
FEED CURRENT
Preset feeder auger motors current. Overcurrent
protection threshold
A
6
1
9,9
6
1
9,9
PAR47
GRATES CURRENT
Grate motor overcurrent protection threshold
A
2
0,2
6
2
0,2
6
PAR48
CLEANING CYCLE
Pre-set time between two cleaning cycles 0=CLEANING
OFF
min
30
0
250
30
0
250
PAR50
RELAY ERROR
ERR output function selection
1/2
1
1
2
1
1
2
PAR52
SMS COUNT
Selecting number of phones receiving alert SMS
X
1
0
5
1
0
5
PAR53
TEMP.TYPE
Determines temperature sensor type plugged in TMP1
connector
-
0
0
10
0
0
10
PAR54
TEMP.LEVEL
Set point value for temperature sensor plugged to
TMP1
°C
70
30
200
70
30
200
PAR55
TEMP.HYST
PAR54 maximum set point hysteresis
°C
5
2
10
5
2
10