PELLA
®
DESIGNER SERIES
®
BETWEEN-THE-GLASS BLINDS AND SHADES WITH INSYNCTIVE
®
TECHNOLOGY
|
6
• Press and release the Down button to send BLIND or
SHADE to its lower position. If you would like to change
this position, follow the procedure for Programming the
Lower Position on page 7 of this product guide.
• Press and release the Center button to send BLIND or
SHADE to its user position. The user position is set by
the factory at approximately 50% of the distance between
fully opened and fully closed positions. If you would
like to change this position, follow the procedure for
Programming the User Position on page 7 of this
product guide.
• Press and release the Up button to send BLIND or
SHADE
to its upper position. If you would like to change
this position, follow the procedure for Programming the
Upper Position indicated below.
• BLIND or SHADE is now ready for use.
PROGRAMMING POSITIONS
See
InsynctiveSupport.Pella.com
for how-to videos.
REMOTE may be used to program up to three positions to
BLIND or SHADE with Insynctive
®
technology, including an upper
position, user position and lower position. Once placed into
program mode, REMOTE will stay in program mode until the
programming process is completed, or REMOTE will automatically
exit program mode if no buttons are pressed for 1 minute or if
battery is removed and reinserted.
Programming Upper Position
• Touch the top end of REMOTE to BLIND or SHADE cover
approximately 6" from the end where the wire connects.
Move REMOTE back and forth slowly until BLIND or SHADE
completes a quick up/down motion to indicate BLIND or
SHADE has entered program mode.
• Simultaneously press and hold the Center and Up buttons
until BLIND or SHADE completes a quick up/down motion.
This will require the buttons to be pressed for about 5
seconds. The light on REMOTE will begin blinking when
the buttons are released to acknowledge that REMOTE is
in program mode.
DETAILED INSTRUCTIONS
(continued)
UP
BUTTON
DOWN
BUTTON
LED
LIGHT
CENTER
BUTTON
COVER
REMOTE
MEASURE 6"
FROM END WHERE
WIRE CONNECTS