Lower the lift
•
Turn the power switch (A). Press down (down
1, F), the lift is lowered to a level of about 20 cm
and stops.
•
Press down (down II C) warning signal sounds
and the warning light (D) lights up. The lift now
goes down the last 20 cm.
•
Turn off the power switch when the lift is
completely down.
•
Remove the rubber blocks and drive the vehicle
from the lift.
Note: When lowering, the down buttons need to be
held down for about 5 seconds before the lift starts
to go down.
•
Emergency lowering in the event of a power
failure
Lift up the steel latch with a steel wire to release
the safety latch.
Open the valve by pushing in and turning counter
-
clockwise. The valve opens and the lift is slowly
lowered. Close by pushing in and turning
clockwise.
Note: Before lowering the emergency, make sure
that the main switch is in the OFF position to
ensure that the lift does not start after a possible
power failure.
Maintenance
Simple maintenance makes the lift work reliably
and last longer. How often you service your lift is
up to you and it is controlled by how much you
use it. However, we recommend that you do this at
least once a year.
Daily check - before use
The user must perform daily checks. Daily
inspection of the safety catches is extremely
important. Detecting a possible fault before use
prevents injuries and accidents.
•
Check all hoses and connections for leaks
•
Check electrical connections. Make sure they
are in good condition.
•
Check that the expander bolts are properly
tightened.
•
Before use, check that the catches work - you
can hear them falling into the socket of the bar
when raising the platforms.
Weekly check
•
Check the flexibility of moving parts.
•
Check the function for safety details.
•
Check the oil level in the tank, it is correct if the
sled goes up in its highest position. If there is
too little oil - top up.
•
Check that the expander bolts are properly
tightened.
Monthly check
•
Check that the expander bolts are properly
tightened.
•
Check all hoses and connections for leaks.
•
Check wear and lubrication on all moving
parts - replace worn parts in time. So there are
no malfunctions.
Annual check
Drain the hydraulic oil.
Important: Think about environmental protection
and dispose of used oil in a suitable way to a
recycling center.
•
Clean the tank and oil filter.
•
Top up with new oil (VG32).
If the user follow these recommendations, the lift
will last a long time and accidents will minimize.
Troubleshooting
Important! If you are unable to remedy the error on
your own, do not hesitate to contact our workshop
on telephone 033-20 26 56 or e-mail
[email protected]. The easiest way is if
you can email a photo of your problem and the
serial number on the machine, it is easier to
remedy the error and we save time for everyone.
Содержание 511754
Страница 1: ...Full rise scissor lift 3000 kg Saxlyft h glyftande 3000 kg Item No 511754...
Страница 3: ......
Страница 12: ......
Страница 14: ...Elschema...
Страница 15: ......
Страница 17: ......
Страница 26: ......
Страница 28: ...Wiring diagram...
Страница 29: ......
Страница 42: ...Koblingsskjema...
Страница 56: ...Ledningsdiagram...
Страница 70: ...S hk kaavio...
Страница 72: ...Verktygsboden Erfilux AB K llb cksrydsgatan 1 SE 507 42 Bor s Verktygsboden Bor s Sweden 0120504 03...