background image

GB -

Paul Hochköpper GmbH & Co. KG

Postfach 1727 • D-58467 Lüdenscheid • Tel.: +49 (0)2351 185-0 • Fax: +49 (0)2351 27666 • e-mail: [email protected] • Internet: www.peha.de 

453 FU-RP ST (Rev0_070830)

126342-01

5.  Operation and functions

5.1  Operation

Manual operation of this device is not possible. The receiving and sending of Ea-

syclick radio signals is done automatically.

5.2  1-level operation  

In -level operation, a radio signal received from a transmitter (LED  blinks red) will 

be passed on to the respective receiver.

Activating 1-level operation:

Press button  LEV  longer than 2s  

a

 LED  lights up for about 3s 

                                          (-level operation is active)

5.3  2-level operation

In 2-level operation (LED 2 blinks red) a transmitter’s radio signal will be received 

and passed on over a maximum of two repeaters to the respective receiver.

Activating 2-level operation:

Press button 2 LEV longer than 2s  

a

 LED 2 lights up for about 3s

                                           (2-level operation is active)

6.  Troubleshooting & remedies

6.1  New system or existing system

•  Check the power supply (electrician only).

•  Check the system’s surroundings for changes that could cause interference 

  (e.g. metal cabinets, furniture or walls which have been moved).

•  If the transmitter/receiver operates at a reduced distance from the  repeater, the 

  radio signal was encountering interference or it was operating outside the trans-

   mission range.

•  Use the repeater at a better location.

6.2  Radio signal range limitations

•  Use of the repeater in the vicinity of metal objects or materials with metal compo- 

  nents. Maintain a distance of at least 0 cm.

•  Moist materials.

•  Devices which emit high-frequency signals (e.g. audio and video systems, com-   

  puters, electronic ballasts in light fixtures). Maintain a distance of at least 0.5 m.

6.3  Contact

Telephone:.............. +49 (0)235 85-0

Fax: ........................ +49 (0)235 27666

Internet:..................  www.peha.de/contact.aspx

Email: ..................... [email protected]

7.  Conformity declaration

PEHA  Easyclick  products  may  be  sold  and  operated  in  EU  countries  as  well  as 

in  CH,  IS  and  N.  PEHA  herewith  declares  that  this  repeater  (453  FU-RP  ST)  is 

in compliance with the fundamental requirements and other relevant provisions of 

R&TTE-Guideline 999/5/EG. The conformity declaration is available in Internet at 

the following address: www.peha.de/ServiceDownloads.aspx.

1.  General

1.1  Application

This repeater is used to increase the range between Easyclick transmitters and re-

ceivers. In -level operation, a radio signal received from a transmitter will be passed 

on to the respective receiver. In 2-level operation a radio signal can be passed over 

a maximum of two repeaters to a receiver!

Notes: 

– The repeater is factory preset for -level operation when delivered.

– Read through the operating instructions carefully before putting the unit into service.

1.2  Guarantee conditions

These operating instructions are an integral part of both the device and our terms of 

warranty. They must be furnished to the user. The technical design of the appliance 

is  subject  to  change  without  prior  notification. 

PEHA

  products  are  manufactured 

and quality-checked with the latest technology according to applicable national and 

international regulations. Nevertheless, if a product should exhibit a defect, 

PEHA

 

warrants to make remedy as follows (regardless of any claims against the dealer to 

which the end-user may be entitled as a result of the sales transaction):

In the event of a justified and properly-established claim, 

PEHA

 shall exercise its 

prerogative to either repair or replace the defective device. Further claims or liability 

for consequential damages are explicitly excluded. A justifiable deficiency is one in 

which the device exhibits a structural, manufacturing, or material defect that makes it 

unusable or substantially impairs its utility at the time it is turned over to the end-user.

The warranty does not apply to natural wear, unintended usage, incorrect connec-

tion, device tampering or the effects of external influences. The warranty period is 

for 24 months from the date of purchase by the end-user from a dealer and ends not 

later than 36 months after the device’s date of manufacture. German law is applica-

ble for the settlement of warranty claims.

1.3  Disposal of the device

Disposal of the device must be done in compliance with the laws and standards of 

the country in which the device is operated!

2.  Safety

CAUTION! Danger of electrical shock!

Current-carrying components are present inside the housing. Con-

tact can lead to personal injury! All work on the mains network and 

the device may only be done by an authorised electrician.

•  Remove power from the device.

•  Check that the device is powered off.

•  Close the housing securely before applying power.

This device is only intended to be used for its stated application. Unauthorised conver-

sions or changes are forbidden! This device may not be used in conjunction with other 

devices whose operation could present a hazard to persons, animals or property.

3.  Technical specifications

4.  Commissioning

4.1  Safety notices

•  Do not use outdoors (indoor use only).

•  Avoid extreme temperatures, moisture and jarring.

•  Use only in CE approved electrical outlets.

4.2  Commissioning

The repeater should be used in an area between the Easyclick transmitter and re-

ceiver. Radio signals received from the transmitter can then be optimally passed on 

to the receiver.

•  Plug the repeater into a conventional SCHUKO electrical outlet.

• 

The repeater is factory preset for 1-level operation when delivered.

  Change the repeater to 2-level operation if this is desired (see Point 5.3).

Installation and Operating Instructions

Easyclick 2-level repeater in plug housing

Art. no.:

 

453 FU-RP ST

GB

Button 1 LEV with LED 1

Activates -level operation

Receive radio signal: LED blinks red 

1 LEV

2 LEV

Button 2 LEV with LED 2

Activates 2-level operation

Receive radio signal: LED blinks red 

1 LEV

2 LEV

LRN/SET

CLR/MODE

N N L L 1

1

L max.2500W

µ

230V~

50Hz

9

mm

451 FU-EP o.T.

1 LEV

2 LEV

LRN/SET

CLR/MODE

N N L L 1

1

L max.2500W

µ

230V~

50Hz

9

mm

451 FU-EP o.T.

1 LEV

2 LEV

Wall transmitter

1-level operation

Receiver

1 LEV

2 LEV

LRN/SET

CLR/MODE

N N L L 1

1

L max.2500W

µ

230V~

50Hz

9

mm

451 FU-EP o.T.

1 LEV

2 LEV

LRN/SET

CLR/MODE

N N L L 1

1

L max.2500W

µ

230V~

50Hz

9

mm

451 FU-EP o.T.

1 LEV

2 LEV

Wall transmitter

2-level operation

Receiver

2-level operation

Transmit frequency

868,3 MHz

Power supply

230V~ / 50 Hz

Ambient temperature

- 20° to + 40° C

Storage temperature

- 40° to + 85° C

Test specifications

EN 60669-2-1

Certifications

CE

Protection type

IP 20