background image

Paul Hochköpper GmbH & Co. KG • Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: [email protected] • Internet: www.peha.de

 

GB - 2 

941 STM (Rev05_090827)

126290-04

11. Technical data

12. Warranty

These operating instructions are an integral part of both the device and the terms of warranty. 

They must be furnished to the user. The technical design of the device is subject to change 

without prior notification.

PEHA 

products are manufactured using state of the art technologies in compliance with 

prevailing national and international regulations, and are quality-tested. 

If the product should, however, reveal any defects, 

PEHA 

agrees to correct these defects 

without affecting the rights of the end user to assert claims against the vendor arising from 

the purchasing contract, as follows:

If the complaint is justified and properly filed, 

PEHA 

can choose to either correct the defect 

or supply a functioning product. Claims above and beyond this, or compensation for follow-

on damages are excluded. The  device 

is deemed to be justifiably defective when it is 

supplied to the end user in an unusable or severely impaired state as a result of a design, 

manufacturing or material error. 

The warranty does not apply to natural wear and tear, improper use, incorrect connection, 

interference with the device or external impacts. 

The warranty period runs for 24 months from the purchase of the device by the end user 

from a vendor, and expires at the latest 36 months after manufacture of the device . The 

settlement of warrantee claims is subject to German law.

13. 

Displays and menu structure

During normal operation of the control module, the company name, the version, the 

weekday, the time and the current date is shown in the control modules display.

To improve the readability in poorly lit installation situations the display of the control 

module features back lighting. It is switched on for about 30 seconds any time a button 

is pressed.

Note:

 In older version of the PHC system software the version V1.99 is displayed instead 

of the current control module version V2.XX.

Using the display and the control modules buttons PROG, 

, ENTER the time of 

the control module can be changed and all timers that were defined during the system's 

programming can be modified. Additionally diagnosis functions (bus voltage and events) 

can be called up. 

13.1 Indication of events

The control module records events in an event list, which allows for a diagnosis. Up to 8 

events can be administrated with a time stamp. Older events are overwritten.

The most important events:

1002......................................Reset button (restart)  

1004, 1005, 100C, 100D  .....Power failure (restart)   

1006, 1007, 100E, 100F  ......Power f reset button (restart)

1028 .....................................Power loss <13 V (restart)

1660 .....................................Clock component reset 

With 7000-series events a problem can be solved by a retransfer of the total project in 

all control modules and a POR release.

With 8000-series events the PHC system should be checked for device failures, wrong 

addresses, or other disturbances.

3 Diagnosis

End

Button 

PROG

Button 

PROG

Selection 1 o. 2

(with button 

)

3 Button 

ENTER

Power Supply:

    24.0V

1 Power Supply

2 Event List

Selection Event

(with button 

)

Event:1 

 

1005

19.07. 

08:43:02

1 Button 

ENTER

2 Button 

ENTER

2 Time switches

3 Diagnosis

2 Button 

ENTER

Timer  

On  12:35

004  

Off  23:45

Button 

ENTER

Button 

ENTER

Selection Timer

(with button 

)

Button 

Button 

Timer  

On  12:35

004  

Off  23:45

Timer   MoTuWeThFr

004  

On 

SaSu

Timer   MoTuWeThFr

004  

Off 

SaSu

Button 

ENTER

Button 

ENTER

Selection Day ON

(with button 

, ENTER)

Selection Day OFF

(with button 

, ENTER)

Set times

(with button 

, ENTER)

Button 

PROG

Peha PHC  V2.00

Tu  19.07.    08:56

Button 

Button 

Button PROG

1 Set time

2 Time switches

Time  

Tu 08:56

Date  

19.07.06

1 Button

ENTER

Button 

PROG

Set time and date

(with button 

, ENTER)

13.2 Indication of the power supply

The  current  power  supply  can  be  viewed  in  the  diagnosis  menu  „

Power  Supply

“ 

(normally 24-30V). At a value below 24 V a further power supply needs to be installed 

at a suitable place. 

Please note:

 The indicated measured value is valid only for this point of the bus line. At 

further distant bus devices the power supply may be lower.

13.3 Flow diagram menu structure

Art. No. 

941 STM AN 

Power supply 

Nom. 24 V DC (SELV) 

21-28 V DC (ripple voltage 5 %) 

Own consumption 

60 mA 

In-/outputs module bus 

(PHC bus) 

2 x modular sockets 6-pin 

4 x screw terminals (0V, +A, -B, 24V) 

In-/outputs ext. PHC bus 

3 x screw terminals RS 485 (-B, +A, 0V) 

Programming interfaces 

for PC 

1 x USB 1.1 (driver needed)  

1 x mini-DIN port RS 232 

5 x screw terminals RS 232 

DCF receiver port 

3 x screw terminals (0V, antenna, +5V) 

Programming 

PHC software 

Clock

Power reserve 8h (in case of power failure)

Time switches 

126 clocks 

Clock programming 

PHC software or manual (4 buttons) 

Display 

3 mm, 2 x 16 characters 

Coding 

DIP switch, 5-pin (module address) 

Ambient temperature 

+10° to +50

°

C

Storage temperature 

 -20° to +60°C 

Screw terminals 

max. 2 x 1.5  mm 

2

Test specifications 

EN 60669-2-1 

Certifications 

KEMA/KEUR, CE 

Protection level 

IP 20 

Dimensions 

DIN housing  width   = 108 mm 

 

height  =  55 mm 