31
Group 1.
INPUT
1100/1101
Disable/Enable the door monitoring function with
enforce entry and door open too long .
1200/1201
Disable/Enable the security function with enforce
1500/1501
Not compare/ Compare individual personal map.
1600/1601
Not compare/ Compare personal time zone map.
1700
Immediately check APB (anti-pass back)
1800/1801
Not compare/ compare holiday.
*
1900/1901
Not compare/ compare project number.
( for p p p . c c c c c format only)
Group 2. OUTPUT
21tt
tt:
Door release time from 01 to 97 in unit of 1
second
.
2198:
Setting door release time becomes
minute
unit,
press
2198
again, door release time back to
second
unit.
2199:
Output becomes normality, both on or off to
switch.
22tt
Alarm time. tt= 00 to 98 in unit of 1 second.
23tt
tt:
Door monitoring time from 01 to 98 in unit of 1
second
.
2399:
Setting door monitoring time becomes
minute
unit, press
2399
again, door monitoring time back to
second
unit.
240n
Trial error alarm, n= error times.
25tt
tt:display time from 01 to 97 in unit of 1 second.
2600/2601
Disable/ enable expiry date check (validity date
programmed by PC only).
*
2700
Display fix duty name by ROM.
*
2701
Definable duty name by PC.
*
2702/04/08
2/ 4/ 8 digit duty name.