11
2750/3750/85/6750V PG-OUTMOD-8 Relay Box
9 Pin Blue Connector J5-7 Pin Blue Connector
Color Signal Name Color Signal Name
No1.Red +12V
No1.Red +12V
No2.Black GND
No2.Black GND
No3.Brown
No3.Orange No Connection
No4.Orange No4.Purple Serial Printer Input
No5.Yellow
No5.Black No Connection
No6.Green
No6.Gray No Connection
No7.Blue No7. Gray No Connection
No8.Purple
No9.Gray Serial Printer Output
2750/3750/85/6750V PG-OUTMOD-24A Relay Box
9 Pin Blue Connector
J5-9 Pin Blue Connector
Color Signal Name Color Signal Name
No1.Red +12V
No1.Red +12V
No2.Black GND
No2.Black GND
No3.Brown
No3.Brown No Connection
No4.Orange No4.Orange Serial Printer Input
No5.Yellow
No5.Yellow No Connection
No6.Green
No6.Gree No Connection
No7.Blue No7. Blue No. Connection
No8.Purple
No.8 Purple
No9.Gray Serial Printer Output No.9 Gray
System Initialize (default password 246890)
Please set the F4 = 0016 / F4 = 0018 / F4 = 0019 / F4 = 0 072 to prevent the
time zone data occupy memory and further caused the card number can not be
enrolled.
The system initialization means the system parameters are defaulted by
F4=0850(off-line mode) or F4=0750(on-line mode). Then the user could
modify some parameters based on it. After each modification to individual
requirement, the user may backup them by code F4=0650. Once the
parameters are destroyed, the code F4=0950 could be applied to restore it.
Controller and Relay Box Wiring Example
Содержание PP-6750V Series
Страница 11: ...6 Bottom View Panel Description ...
Страница 13: ...8 Example of how to wiring ...
Страница 14: ...9 ...
Страница 45: ...40 Appendix ...