Pegasus FlyAway Kit
52
___________________________________________________________________
Columbia Weather Systems, Inc.
Dew Point
B = (ln (RH/100) + ((17.2694*T) / (238.3+T))) / 17.2694
Dew Point in °C = (238.3 * B) / (1-B)
Where:
RH = Relative Humidity
T = Temperature in °C
Ln = Natural logarithm