Pegasus FlyAway Kit
31
___________________________________________________________________
Columbia Weather Systems, Inc.
T1: will display the temperature for the first temperature probe in
degrees F
T2: will display the temperature for the second temperature probe in
degrees F
T3: will display the temperature for the third temperature probe in
degrees F
T4: will display the temperature for the fourth temperature probe in
degrees F
LW: will display leaf wetness in volts. The range may vary per
sensor. Typically, 0.5 volts indicates saturated condition and 4.5
volts indicates dry conditions.
X1 and X2 channels are not used with the Pegasus FlyAway Kit
Datalog
The Pegasus weather station has a built in circular datalogger. The
datalog holds records of sensor readings (Samples) and High/Low
information. Both types of records (Samples and High/Low) are
recorded at user defined intervals.
The datalog can hold up to 511 records. A Sample occupies on
record and High/Low information occupies four records.
Setting datalog intervals
The interval for the Sample records in the datalog is user selectable.
The interval duration is restricted to the following: 1, 2, 3, 4, 5, 6, 10,
15, 20, 30, and 60 minutes.
n MEAS-INT: This command sets the Sample interval in the datalog.
n is the interval duration in minutes.
Example: 15 MEAS-INT will cause the weather station to save a
Sample record every 15 minutes.
Setting Hi/Lo intervals
The interval for the High/Low records in the datalog is user
selectable. The interval duration is restricted to the following: 1, 2, 3,
4, 6, 8, 12 and 24 hours.
n HI/LO-INT: This command sets the High/Low interval in the
datalog. n is the interval duration in hours.
Example: 12 HI/LO-INT will cause the weather station to save
High/Low records (total of four records) every 12 hours.