Pegasus FlyAway Kit
29
___________________________________________________________________
Columbia Weather Systems, Inc.
Setting date and time
SET-DATE: This command is used to set the internal calendar to
the appropriate date. It uses space delimiters between the month
field, the day field, the year field, and the command field.
Example: 12 25 96 SET-DATE sets the date to 12/25/1996 and 1 5
01 SET-DATE sets the date to 1/5/2001
SET-TIME: This command is used to set the internal clock to the
appropriate military time (24 hours clock). It uses space delimiters
between the hours field, minutes fields and the command field.
Example: 13 46 SET-TIME sets the time to 1:46 PM
Displaying date and time
DATE-TIME: This command is used to display the system date and
time. When used the weather station will return the date followed by
the time, comma delimited.
Example: 02/11/1998,13:20ok
Displaying current sensor readings
There are three ways to display current sensor readings:
The POLL command
POLL: This command is used to display the current sensor readings
in a report format. When a POLL command is issued, the weather
station will interrogate all the sensors and will display the
information
Example:
11:00
Time
02/11/1998 Date
50.14
Degrees F
Temperature 1
70.89
Degrees F Temperature 2
68.33
Degrees F Temperature 3
64.46
Degrees F Temperature 4
29.88 Inches Hg
Barometric Pressure
006 MPH
Wind Speed
SE
Wind
Direction
073 Percent
Relative Humidity
00.06 Inches
Rain (Today)
04.43 Volts
Leaf Wetness
01.30 Volt
X1
04.58 Volts
X2
ok