![PEGASUS TECHNOLOGY GRTD-TH3 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/pegasus-technology/grtd-th3/grtd-th3_installation-operation-and-maintenance-manual_1521931025.webp)
www.pegasustech.com.br
24
CONNECTION TO THE GENERATOR WITH AUXILIARY WINDING
Notes:
1
For work only isolated (single) short circuit
S1
e
S2
;
2
If possible use a 10A/300Vca circuit breaker in series with terminal 3 connection to turn the
regulator on and off.
3
Droop CT is not provided by PEGASUS, observe ratio specification (PAR/1A or PAR/5A)
4
Generator line voltages, according to the sensing voltage class and the supply voltage level of
the regulator.
Attention
➢
Before connecting the regulator to the generator, refer to the installation manual for the
nominal reference voltage;
➢
The supply voltage
can’t exceed
the maximum voltage specified by the product
;
➢
If the reference voltage is note qual to the output voltage of the generator, do not make the
connections without consulting the service center.
➢
Using auxiliary winding, the E
3/4
connector, regulator circuit reference, must be the common
point between coil and generator.
Figure 22
–
Connection with auxiliary winding with generator operating in the range of 160 à 300Vca [E1] or 330 à 600Vca [E2]
Generator
Load