HOW TO CONNECT TO THE GENERATOR
DESCRIPTION OF GENERATOR CONNECTION TERMINALS
The connection of the regulator to the generator is made through
faston
type connector. The
identification of the connectors is shown below in figure 19.
The table 3 shown the terminal list and its function.
Connector
Function
E
3/4
Common reference for power supply and sensing voltage
3
Power supply
E1
Reference voltage input (sensing) (160-300 Vca)
E2
Reference voltage input (sensing) (330-600 Vca)
F-
Negative excitation field connection
F+
Positive excitation field connection
S1, S2
Droop TC connection
A+, A-
Analog input
DW, CM, UP
Digital input
Auxiliary Contact
Status relay of regulator protections (NF-ok /NA-fault)
Table 3
–
Regulator terminals identifications
Figure 19
–
Identification of connection terminals