E. USER MENU
The User menu is accessible from the default screen by
pressing the M button once to enter the menu level
selection screen and pressing M again when “0000” is
shown in the small digits.
The User Menus allow access to basic setpoints, system
test, and unit settings. Use buttons R1 and R2 to move
between parameters.
F.
STATUS MENU – 1000 LEVEL
The Status Menu is accessible from the default screen by
pressing the M button once to enter the menu level
selection screen. Using R1 and R2, select “1000” in the
small digit area. Press M to enter the Status Menu.
The Status Menu allows for in-depth boiler information to
be viewed but cannot access parameters for modification.
33
BOILER CONTROL: INTERNAL WIRING & OPERATION
Table 8.5: User Menus (0000 Level)
User
(0000)
Parameters
Parameter Function
Units/Options
0003
– CH Setpoint, CH enable/disable
Temperature
0048
– DHW Setpoint, DHW enable/disable
Temperature
0200
– 10 minute System Test. Once 10 minute timer is over boiler
will return to normal state.
– Additional Access with Installer access PIN
– Input installer PIN using CODE menu then return to User
Menu for advanced system test functions.
– OFF-System Test Disabled
– FAN-Test blower (fixed speed)
– Lo-Test burner at low power
– Ign-Test burner at igniton power
– Hi-Test burner on high power
– REg-Test burner at high power with supply setpoint enabled
Installer level only:
– Stb-Test maximal thermostat
– LCO1-Test Low Water Cut-off 1
0901
– Temperature unit setting
°C/°F
0902
– Pressure unit setting
Bar/psi
0997
– Screen Test
– Pressing select activates all LCD options
No options
Table 8.6: Status Menus (1000 Level)
Status
(1000)
Parameters
Parameter Function
Value/Options
1001
Supply temperature
Temperature
1002
DHW temperature
Temperature
1004
Outside temperature
Temperature
1005
2nd Supply temperature
Temperature
1006
Flue temperature
Temperature
1007
Return temperature
Temperature
1008
Ionization / flame current
µA
1010
CH Pump
On/Off
1012
Actual CH setpoint
Temperature
1013
Room Thermostat (RT) input
Open/Closed
Содержание PBC-34
Страница 1: ...PBC Gas Boilers PBC 34 PBC 40 PBC 52 Combination Installation Operation Maintenance Manual Series...
Страница 22: ...20 WATER PIPING AND CONTROLS Figure 4 6 Recommended Central Heat Piping...
Страница 23: ...21 Figure 4 7 Recommended Domestic Hot Water Piping WATER PIPING AND CONTROLS...
Страница 31: ...29 Figure 7 2 Wiring Schematic and Connection ELECTRICAL CONNECTIONS...
Страница 45: ...E LIGHTING OPERATING PROCEDURES 43 START UP PROCEDURE...
Страница 57: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 60: ...58 REPAIR PARTS Figure 13 2 PBC 34 Combustion Components...
Страница 62: ...60 REPAIR PARTS Figure 13 3 PBC 40 and PBC 52 Combustion Components...