75
Description
Quantity Required
Stock
Code
PFC-850 PFC-1000 PFC-1500
1
Heat Exchanger - PFC-850
1
–
–
5651
Heat Exchanger - PFC-1000
–
1
–
5652
Heat Exchanger - PFC-1500
–
–
1
5703
2
Burner Mounting Plate (Includes 2A & 2B)
2
2
2
54430
2A
Burner Mounting Plate Fiberglass Rope Gasket
52”
52”
52”
54188
2B
Burner Mounting Plate Rubber Gasket
2
2
2
54655
3
Flame Sensor Electrode (Includes 3A)
2
2
2
54432
3A
Flame Sensor Electrode Graphite Gasket
2
2
2
54605
4
Ignition Electrode (Includes 4A)
2
2
2
54431
4A
Ignition Electrode Graphite Gasket
2
2
2
54123
5
Burner Element (Blue Jet) - 12.1” Long
2
–
–
54656
Burner Element (Blue Jet) - 14.1” Long
–
2
–
54679
Burner Element (Blue Jet) - 20.7” Long
–
–
2
54657
6
Flapper Valve Assembly - PFC-850/1000
2
2
–
54434
Flapper Valve Assembly - PFC-1500
–
–
2
54625
7
Supply/Return Sensor - 1/8” NPT 12 k
D
4
4
4
54438
8
High Limit Switch - 1/4” NPT
2
2
2
54419
9
Header Supply Sensor 1/4” NPT 12 k
D
1
1
1
54418
10
Hex Flange Nut M6 Fine Thread
12
12
12
51614
11
Flapper Valve Screw - M5-0.80 x 16 mm Zinc
10
10
10
–
12
Burner Gasket
2
2
2
54467
13
Ignitor/Flame Sensor Screw - M4 x 8mm Zinc
8
8
8
6507
14
Flue Temperature Sensor - 1/4” BSP 12 k
D
1
1
1
54111
15
Thermal Fuse - 318 C, 605 F
2
2
2
54466
16
Burner Mounting Plate Insulation - PFC-850/1000
2
2
–
54653
Burner Mounting Plate Insulation - PFC-1500
–
–
2
54654
17
Blower Gasket - PFC-850/1000
2
2
–
54504
Blower Gasket - PFC-1500
–
–
2
54505
18
Target Insulation
2
2
2
54185
18A Target Insulation Washer M4 SS Fender
2
2
2
–
18B Target Insulation Screw M4 x 16 SS
2
2
2
–
19
Exhaust Vent Gasket - 6” PFC-850/1000
1
1
–
54658
Exhaust Vent Gasket - 7” PFC-1500
–
–
1
54659
20
Exhaust Vent Clamp - 6” PFC-850/1000
1
1
–
54660
Exhaust Vent Clamp - 7” PFC-1500
–
–
1
54661
REPAIR PARTS
Table 13.1: Heat Exchanger
Содержание PUREFIRE PFC-1000
Страница 1: ...PUREFIRE Boilers PFC 850 PFC 1000 PFC 1500 Gas Installation Operation Maintenance Manual ...
Страница 23: ...21 WATER PIPING CONTROLS Figure 4 4 Recommended Piping One Boiler with Multiple CH Zones One DHW Tank ...
Страница 24: ...22 WATER PIPING CONTROLS Figure 4 5 Recommended Piping Multiple Boilers with Multiple CH Zones One DHW Tank ...
Страница 62: ...60 START UP PROCEDURE J LIGHTING OPERATING INSTRUCTIONS Figure 9 1 Lighting Operating Instructions ...
Страница 80: ...78 REPAIR PARTS Figure 13 3a Jacket Assembly PFC 850 1000 Figure 13 3b Jacket Assembly PFC 1500 ...
Страница 82: ...80 Figure 13 4 Control System REPAIR PARTS ...
Страница 84: ...82 Figure 13 5 Condensate System REPAIR PARTS ...
Страница 89: ...87 APPENDIX B BURNER LCD STATUS SCREENS CH Burn Cycle DHW Burn Cycle Special Functions DHW Tank Warm Hold ...
Страница 90: ...88 APPENDIX C USER MENU APPENDIX C USER MENU Figure C 1 User Menu Managing Burner ...
Страница 91: ...89 APPENDIX C USER MENU Figure C 1 User Menu Dependent Burner ...
Страница 92: ...90 APPENDIX D INSTALLER MENU STRUCTURE APPENDIX D INSTALLER MENU STRUCTURE ...
Страница 93: ...91 APPENDIX D INSTALLER MENU STRUCTURE ...
Страница 95: ...93 SERVICE LOG SERVICE LOG Date Serviced By Description of Service Serial Number ...
Страница 96: ...94 NOTES ...
Страница 97: ...95 NOTES ...