TECHNICAL INSTRUCTIONS
4853989
10/ 2003
Our policy is one of continuous improvement and we reserve the right to alter specifications of our products at any time.
- 10 -
Add or remove shims under the base to level the pump-shaft. The base plate itself does not have to
be level.
Torque down fixing nuts tight against the base plate and observe pump and motor shafts or coupling
hubs for alignment.
Flat plain washers should be used on top of the flanges.
Grout base plate in completely using non-shrink grout and allow it to dry thoroughly before attaching
piping to pump (24 hours is sufficient time with the approved grouting procedure). See procedure
detailed under Channel Section base plate.
The suction and discharge piping should be installed after the pump unit, ensuring that no pipe strain
is placed on either flange, and both pump and pipe flanges are square to each other.
2.6.3 INSTALLATION FOR FOLDED METAL BASE PLATE WITHOUT SIDE FLANGES
Position base plate and, using a long enough bit, drill through the holes in the base plate. It may be
necessary to move the pump unit in order to complete the foundation bolt installation, which should be
done in line with manufacturers instructions.
Use blocks and shims under base for support, either side of foundation bolts and midway between
bolts, to position base approximately 1 inch above the concrete foundation with studs extending
through holes in the base plate.