To prevent tampering with the pitch and roll adjustments

:

  

Tighten the two tamper resistant security screws 

on the projector mount assembly using 4 mm security allen wrench (

I

) to lock the pitch and roll adjustments as 

shown below.

Note:

 Tighten screws firmly, but do not overtighten. Overtightening can damage the mount.

•  Do not adjust pitch or roll while tamper resistant security screws are fully engaged.
•  Loosen the two tamper resistant security screws one complete turn before adjusting the projector mount assembly 

or damage may occur.

CAUTION

TO LOCK ROLL, 

TIGHTEN 

TAMPER  RESISTANT 

SECURITY  SCREW

TO LOCK PITCH, 

TIGHTEN TAMPER  

RESISTANT 

SECURITY  SCREW

FRONT VIEW

SIDE VIEW

11

CEILING INSTALLATION

WALL INSTALLATION

(EXCEPT FOR EXC MODELS)

DD

DD

Adjusting Mount Extension

While supporting the weight of the projector, loosen clamp plate screws half a turn and position projector to the 

desired extended position. Retighten clamp plate screws securely.

CLAMP PLATE 

SCREWS

CLAMP PLATE 

SCREWS

10-1

•  On ceiling installations, clamp plate adjustment screws support weight of projector when fully tightened. Weight of 

the projector will need to be supported if clamp plate screws are  loosened.

 WARNING

Содержание PRG-EXA

Страница 1: ...stments Safety catch designed into extension to ensure user and equipment safety Internal cable management within channels for clean clutter free appearance Includes PRG Series projector mount for precise image alignment Models PRG EXA PRG EXA W PRG EXB PRG EXB W PRG EXC PRG EXC W Max UL Load Capacity 50 lb 22 68 kg ISSUED 04 24 08 SHEET 055 9257 9 02 28 14 2300 White Oak Circle Aurora Il 60502 80...

Страница 2: ... these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Never exceed the Maximum UL Load Capacity See page 1 If mounting to wood stud wall joist ceilings make sure that mounting screws are anchored into the center of the stud Use of an edge to edge stud finder is highly recommended Always use an assis...

Страница 3: ...5 OD 4 540 1025 540 2025 540 1025 540 2025 H 2 mm security allen wrench 1 560 1097 560 1097 560 1097 560 1097 I 4 mm security allen wrench 1 560 9646 560 9646 560 9646 560 9646 J M3 x 8 mm serrated washer head socket pin screw 4 510 1004 510 2004 510 1004 510 2004 K M4 x 10 mm serrated washer head socket pin screw 4 510 1060 510 2060 510 1060 510 2060 L M5 x 10 mm serrated washer head socket pin s...

Страница 4: ...5 9257 9 02 28 14 Visit the Peerless Web Site at www peerless av com For customer care call 1 800 865 2112 Note Actual parts may appear slightly different than illustrated A D J K L M AA BB CC DD EE FF GG HH II JJ KK LL H C B I E F G ...

Страница 5: ...rless Web Site at www peerless av com For customer care call 1 800 865 2112 Install Outer Channel to Ceiling Plate Attach outer channel BB to ceiling plate AA using four M6 x 10 mm socket pin screws II as shown Tighten screws with 4 mm security wrench I AA BB II 1 ...

Страница 6: ...32 4 mm dia holes 2 1 2 65 mm deep Secure ceiling wall plate AA to wood stud or joist using two 14 x 2 1 2 wood screws D and two 1 4 washers F as shown in figure 2 3 Skip to step 3 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that ceiling wall plate is firmly attached but do ...

Страница 7: ...oid or cavity Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor Installer must verify that the supporting surface will safely support the combined load of the equipment and all at tached hardware and components WARNING C BB AA D D BB AA C OPENING ON OUTER CHANNEL BB INDICATES FRONT OF MOUNT CONCRETE CEILING CONCRETE WALL CINDER BLOCK WALL OPENING ON OU...

Страница 8: ... removable from projector routing through channels is not an option Guide projector cables into openings in channels then insert inner channel CC into outer channel BB as shown in figure 3 1 or 3 3 Position inner channel CC to the desired extended position and secure using two M6 x 12 mm socket pin screws HH through clamp plate DD and into inner channel CC as shown in figure 3 2 or 3 4 CEILING INS...

Страница 9: ...lation Position PRG projector mount A to the orientation shown in figure 4 2 and attach to horizontal mounting plate FF using two M5 x 16 mm socket pin screws GG four 1 4 washers F and two locknuts KK NOTE Placing washer F and nut KK combination on inside of PRG projector mount first while attaching mounting bracket EE or FF can make installation easier as shown in figure 4 3 A A fig 5 2 CC EE ARR...

Страница 10: ...low Place projector upside down Locate adapter plate B with notch facing forward as close to projector center of gravity as possible without covering any mounting holes Loosen channels with 4 mm security allen wrench I and if there are only three mounting holes remove fourth channel Using one channel for each mounting hole position feet of channels over mounting holes as shown below Important If p...

Страница 11: ... M and foot adjustment that will result in channels of adapter plate B fitting tightly against projector Important In order to properly engage the threads in the mounting holes the screw must be turned at least 3 full turns NOTE If using screw J place washer G between screw J and foot of channel It is the responsibility of the installer to ensure that the projector is properly ventilated Feet of c...

Страница 12: ...ack of mount as shown below Pull knob out and turn by hand for easy adjustment or insert 2 phillips screwdriver in end of knob and turn To adjust roll side to side tilt Turn knob on side of mount as shown below Pull knob out and turn by hand for easy adjustment or insert 2 phillips screwdriver in end of knob and turn Projector Alignment KNOB FOR ROLL ADJUSTMENT KNOB FOR PITCH ADJUSTMENT BACK OF MO...

Страница 13: ...r resistant security screws one complete turn before adjusting the projector mount assembly or damage may occur CAUTION TO LOCK ROLL TIGHTEN TAMPER RESISTANT SECURITY SCREW TO LOCK PITCH TIGHTEN TAMPER RESISTANT SECURITY SCREW FRONT VIEW SIDE VIEW 11 CEILING INSTALLATION WALL INSTALLATION EXCEPT FOR EXC MODELS DD DD Adjusting Mount Extension While supporting the weight of the projector loosen clam...

Страница 14: ...cables if routed through channels Snap cable covers LL into openings as shown CABLES CEILING INSTALLATION WALL INSTALLATION EXCEPT FOR EXC MODELS CUT TO LENGTH OF OPENING CUT TO LENGTH OF OPENING CUT TO LENGTH OF OPENING CUT TO LENGTH OF OPENING LL LL LL LL BB CC BB CC Install Cable Covers 2013 Peerless Industries Inc All rights reserved All other brand and product names are trademarks or register...

Отзывы: