![Peek Traffic LPM-14-E Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/peek-traffic/lpm-14-e/lpm-14-e_reference-manual_1520186021.webp)
3-10
&Gn - Select Guard Tone
The modem generates the guard tone selected by this command according to the parameter supplied (DPSK modulation modes only). The
parameter value, if valid, is written to S23 bits 6 and 7.
&G0,&G1
Disables guard tone.
&G2
Selects 1800 Hz guard tone.
Result Codes:
OK
n = 0 to 2.
ERROR
Otherwise.
&Jn - Telephone Jack Control
This command is only included for compatibility and performs no function except to load the S-Register. The parameter value, if valid, is
written S21 bit 1.
&J0
&J0 command. (Default.)
&J1
&J1 command.
Result Codes:
OK
n = 0 or 1.
ERROR
Otherwise.
&Kn - Flow Control
This command defines the DTE/DCE (terminal/modem) flow control mechanism. The parameter value, if valid, is written to S39 bits 0, 1, and
2.
&K0
Disables flow control.
&K3
Enables RTS/CTS flow control. (Default for data modem modes.)
&K4
Enables XON/XOFF flow control.
&K5
Enables transparent XON/XOFF flow control.
&K6
Enables both RTS/CTS and XON/XOFF flow control. (Default for fax modem.)
Result Codes:
OK
n = 0, 3, 4, 5, or 6.
ERROR
Otherwise.
&Ln - Leased Line Operation
This command selects leased or dial-up line operation for compatibility. The OK response is returned for a valid parameter, but no other
action is performed. The parameter value, if valid, is written to S27 bit 2.
&L0
Selects dial-up line operation.
&L1
Selects leased line operation.
Result Codes:
OK
n = 0 or 1.
ERROR
Otherwise.
&Mn - Asynchronous/Synchronous Mode Selection
This command determines the DTR operating mode. The modem treats the &M command as a subset of the &Q command.
&M0
Selects direct asynchronous operation. Note that the command sequence &M0\N0 selects normal buffered
mode, but the command sequence \N0&M0 selects direct mode. This is because the \N0 command is
analogous to the &Q6 command. The value 000b is written to S27 bits 3, 1, and 0, respectively. (See &Q).
&M1
Selects synchronous connect mode with async off-line command mode. The value 001b is written to S27 bits
3, 1, and 0, respectively. (Serial interface operation only.)
&M2
Selects synchronous connect mode with async off-line command mode. Same as &M1 except that &M2
enables DTR dialing of directory slot 0. The modem will disconnect if DTR is OFF for more than the period in
S25 (in units of hundredths of a second): the data connection will be synchronous. The value 010b is written to
S27 bits 3, 1, and 0, respectively. (Serial interface operation only.)
&M3
Selects synchronous connect mode. This mode allows DTR to act as a talk/data switch. The call is manually
initiated while DTR is inactive. When DTR becomes active, the handshake proceeds in originate or answer
mode according to S14 bit 7. The value 011b is written to S27 bits 3, 1, and 0, respectively.