3.6. Capacitance
Range
Resolution Accuracy
Overload
protection
60 nF
10 pF
<10nF:
±
(5,0% rdg.
-
50 St.) +20 dgt.
±
3,0 % rdg.+ 10 dgt.
250V DC/AC
eff
600 nF
100 pF
±
5% rdg. + 10 dgt.
6 µF
1 nF
60 µF
10 nF
300 µF
100 nF
3.7. Diode Test
Function Range Reso-
lution
Accuracy
Test
voltage
Test
current
1V
1mV
+/- 1,0 %
1,5V
1mA
Overload protection: 250V DC/AC
rms
3.8. Frequency
Logic frequenzy (1Hz-1MHz)
Range
Resolution Accuracy
Overload
protection
99,99 Hz 0,01 Hz
±
0,1% rdg.+ 3 dgt.
250V DC/AC
eff
999,9 Hz 0,1 Hz
9,999 kHz
0,001 kHz
99,99 kHz
0,01 kHz
999,9 kHZ 0,1 kHz
Linear frequenzy (6Hz-10kHz)
Range
Resolution Accuracy
Overload
protection
99,99 Hz
0,01 Hz
±
0,05% rdg.+ 8 dgt.
250V DC/AC
eff
999,9 Hz
0,1 Hz
9,999 kHz
0,001 kHz