PCAN-PC/104 – User Manual
8
2
Configuration and
Installation
This chapter covers the configuration, the software setup for the
PCAN-PC/104 card under Windows, and the card installation in the
computer.
2.1
Configuring the Card
Before installing the PCAN-PC/104 card into the computer you may
need to configure it. For each CAN channel an interrupt (IRQ) and an
I/O address range is set for operation in the computer.
At delivery the PCAN-PC/104 card has the following default settings:
CAN channel IRQ
I/O address range
Comment
1
10
300h – 31Fh
2
5
320h – 33Fh
Dual Channel model only
Tip:
If the given resources are not permanently allocated by
other devices, you can skip the configuration and directly
continue with the following manual section 2.2.
For a configuration differing from the default settings you need to
set jumpers on the PCAN-PC/104 PCB according to the following
explanations.
Attention!
Electrostatic discharge (ESD) can damage or destroy
components on the PCAN-PC/104 card. Take precautions to
avoid ESD when handling the card.