22
5. Adjusting the current rating of thermal relay in control box according to the different
configurations of hydraulic power unit. In general, the electric current of thermal
relay should equal or larger than that of motor. The following table shows rated
current regulation of thermal relay in case of different hydraulic power unit.
Hydraulic
power unit
PEAK
SPX
Monarch
220V
3HP
380V
3HP
415V
3HP
220V
4HP
380V
4HP
220V
3HP
380V
3HP
220V
3HP
380V
3HP
415V
3HP
Rated current
of thermal
relay
16A
12A
12A
22A
14A
18A
12A
16A
12A
12A
Fig. 34
Using cross
screwdriver to adjust
rated current value of
thermal relay
This point shows
the present rated
current value
Содержание AMGO 409
Страница 1: ...0 FOUR POST LIFT Model 409 A440...
Страница 9: ...7 D Install cross beams See Fig 11 Fig 12 3 1 3 Fig 12 Hole towards inside 2 Fig 11...
Страница 33: ...31 IV EXPLODED VIEW Model 409 A440 Fig 46 13...
Страница 34: ...32 CROSS BEAM CYLINDERS Fig 47 Fig 48 3...
Страница 35: ...33 CONTROL BOX SPX ELECTRIC POWER UNIT 220V 5HZ single phase Fig 50 Fig 49 Fig 50...
Страница 50: ...8 72114202 12 2015...