19
High limit swit
ch
wire
○
C
Connecting 11
#
& 12
#
(NC)
of limit switch to terminals
3
#
& 5
#
of control box
When the cross beam is lowered to 300mm,
the slider will access to the drive lever of
lower limit switch, and stop the lift.
51
34
45
3
N. Install electrical system
1. Install high limit switch
(See Fig. 30)
2. Install lower alarm limit switch
(See Fig. 31)
Fig. 30
Fig. 31
1
40
43
42
61
39
Connecting 13
#
& 14
#
(NO)
of limit switch to terminals
8
#
& 10
#
of control box
Lower limit swit
ch
wire
○
D
300mm