Page 5

Warranties and Liabilities

1.  The Company warrants that it has title to the Goods.
2.  Subject to the provisions of this clause the Company warrants that the Goods    

shall comply in all material respects with any specification referred to in the Order  

Confirmation (as the same may be amended) and shall, subject thereto, be free   

from defects in material and workmanship for the lesser of a period of twelve    

months from the date of delivery or thirteen months from the date of dispatch    

from the factory.

3.  Save as provided in this clause and except where the Goods are sold to a person  

  dealing as a consumer (within the meaning of the Unfair Contract Terms Act    

1977) all warranties, conditions or other terms implied by statute or common  

law are hereby expressly excluded save to the extent they may not be lawfully 

excluded. When the Goods are sold to a consumer within the meaning of the Unfair 

Contract Terms Act 1977 their statutory rights are not affected by the provisions of 

this clause.

4.  In the event of the Customer making a claim in respect of any defect in terms of  

  clause 2 hereof the Customer must. 

1.  Reasonably satisfy the Company that the Goods have been properly installed, 

commissioned, stored, serviced and used and without prejudice to the generality 

of the foregoing that any defect is not the direct or indirect result of lack of repair 

and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or 

incorrect spare parts 

2.  Allow the company to inspect the Goods and/or any installation and any 

relevant packaging as and when reasonably required by the Company.

5.  Subject to the Company being notified of any defect as is referred to in sub- 

  clause 2 hereof within a reasonable time of it becoming apparent and subject 

always to the terms of sub-clause 4 hereof, the Company shall, in its option, replace 

or repair the defective Goods or refund a proportionate part of the Price. The 

Company shall have no further liability to the Customer (save as mentioned in sub-

clause 6 hereof).

6.  The Company shall be liable to indemnify the Customer in respect of any claim 

for death or personal injury to any person in so far as such is attributable to the 

negligence or breach of duty of the Company or any failure by the Company to 

comply with the provisions of sub-clause 2 hereof.

7.  Save as provided in sub-clause 2 hereof the Company shall not be liable in respect 

of any claim by the Customer for costs, damages, loss or expenses (whether direct, 

indirect, consequential or otherwise) or indemnity in any respect howsoever arising 

including, but not by way of limitation, liability arising in negligence (other than 

pursuant to clause 6 above) that may be suffered by the Customer or any third 

party.

Содержание NG2000A

Страница 1: ...NG3000 5000 User Manual Rev 2 RSID 197 06 10 21 NG3000 A 5000 A User Manual...

Страница 2: ...al Specification 9 Unpacking 13 Installation 14 Generator Environment 14 Removing the generator from the shipping crate 15 Generator Overview 16 General Dimensions 16 Removal of Transit Brackets 17 Wa...

Страница 3: ...can refer to the contents page to find the relevant information Please review each of the following sections carefully Thank you for selecting Peak Scientific to meet your gas generation needs and sh...

Страница 4: ...works to your schedule Remove the hassle and safety concerns with ordering and replacing pressurized cylinder gas 12 month comprehensive on site warranty Delivering flow rates of 3000cc min or 5000cc...

Страница 5: ...ality of the foregoing that any defect is not the direct or indirect result of lack of repair and or servicing incorrect repair and or servicing use of wrong materials and or incorrect spare parts 2 A...

Страница 6: ...ted conditions are fully understood or met A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause...

Страница 7: ...irective 2014 35 EU EN 61010 1 2010 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Electromagnetic Compatibility Directive 2014 30 EU EN 61326 1 2013 Electrica...

Страница 8: ...The Electrical Equipment Safety Regulations 2016 SI 2016 1101 as amended BS61010 1 2010 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use The Electromagnetic Com...

Страница 9: ...ance Notes PDF produced by the Department for Business Innovation and skills for the UK and here for Europe All PEAK products that are subject to the WEEE directive are compliant with the WEEE marking...

Страница 10: ...minimum of 3 hours before operation Inlet Conditions Minimum Air Pressure 8 2 bar 120 psi Maximum Air Pressure 8 8 bar 130 psi Generator Outlets Maximum Gas Output Pressure 5 5 bar 80 psi Maximum Outl...

Страница 11: ...lowed to acclimatize at room temperature for a minimum of 3 hours before operation Generator Outlets Maximum Gas Output Pressure 5 5 bar 80 psi Maximum Outlet Flow Rate 3000 cc min 0 10 cfm Particles...

Страница 12: ...minimum of 3 hours before operation Inlet Conditions Minimum Air Pressure 8 2 bar 120 psi Maximum Air Pressure 8 8 bar 130 psi Generator Outlets Maximum Gas Output Pressure 5 5 bar 80 psi Maximum Outl...

Страница 13: ...lowed to acclimatize at room temperature for a minimum of 3 hours before operation Generator Outlets Maximum Gas Output Pressure 5 5 bar 80 psi Maximum Outlet Flow Rate 5000 cc min 0 17 cfm Particles...

Страница 14: ...e Peak Partner from where the unit was purchased Follow the unpacking instructions posted on the side of the crate It will require two people to remove the unit from the shipping crate and to manoeuvr...

Страница 15: ...s affected by ambient conditions Note should also be taken to the proximity of Air Conditioning outlets These can sometimes give rise to pockets of air with high relative humidity Operation of the uni...

Страница 16: ...e top half of the crate can be slid backwards and away from the rest of the crate With the top of the crate removed the foam insert of top of the generator should also be taken off The generator can n...

Страница 17: ...e 17 Generator Overview General Dimensions The generator must always be placed on a flat level surface Failure to do so will affect the performance of the generator WARNING 430 00 mm 410 00 mm 1235 00...

Страница 18: ...r To remove the transit bracket first remove the 11 screws on the front panel as shown then remove the front panel from the generator Now locate the red transit bracket attached to the compressor foot...

Страница 19: ...rning label Remove the screw from the generator this should be repeated for the other side of the unit and retain Next using the screw which was removed fit the bracket and washers provided to the gen...

Страница 20: ...the left side of the unit The upper port is the Compressed Air inlet and the lower is the Nitrogen outlet A 8 Swagelok fitting is supplied for connection to the application There is no drain on this m...

Страница 21: ...o the mains supply please check the information on the serial plate The mains supply must be of the stated AC voltage and frequency EARTH GROUND E Green Yellow or Green LIVE L Brown or Black Neutral N...

Страница 22: ...f the vent cycle the inlet valve will open and the normal operating cycle will begin Pressure should begin to build on the gauge on the front panel reaching 80 psi after approximately 10 minutes The g...

Страница 23: ...tilizes a unique single column system where the column is alternately pressurised and vented under a finely tuned timing cycle The rates of pressurisation and venting are accurately set which guarante...

Страница 24: ...ilencer Element 02 1016 1 A Versions only As an alternative to purchasing the 12 month service items individually an Annual Service Kit is available as one part number This contains all the filters re...

Страница 25: ...to install and setup your generator IQ OQ Certified assurance for applications requiring documented qualification Complete plan Swift response by a Peak Service Engineer within 72 hours planned preven...

Страница 26: ...he cloth prior to use Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator Under no circumstances should any solvents or abrasive cl...

Страница 27: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Страница 28: ...industry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator cover and payment options speak...

Отзывы: