background image

Page 14

Go Online or Complete and Return

You can register for your 

FREE 12 month Warranty 

with ease online at 

www.peakscientific/protected

.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at 

[email protected]

.

Product Warranty Registration

Contact name

Email address

Company

Address

City/town

Postcode

Country

Telephone

Generator serial #

Model type

Installation date

Do you still use an 
alternative gas solution i.e. 
cylinders or bulk liquid?

Yes                 No

What gas requirements do 
you have in your lab?

Hydrogen             Nitrogen            Zero Air

Extend your cover with

Peak Scientific offer comprehensive gas generator after sales support packages.  
Peak [Protected] aftercare support can guarantee an on-site response within 
72 hours*, genuine parts from our ISO9001 approved factory and a 95% first-time 
fix rate.  See our enclosed Peak [Protected] leaflet for further information.

Important!

You have 1 month to register your Peak Scientific product from the date of installation. Once registered 

the warranty will be honoured for a period of 12 months. If you wish to defer the installation of your 

generator, you must notify Peak Scientific immediately by emailing [email protected]

For generators that remain unregistered after 1 month from the shipment date, the warranty will be 

considered active from the date of factory dispatch.

* Complete Plan only

Go Online or Complete and Return

We know that registering any of your recently purchased products is not the 

first thing on your mind- but it is very important to both of us. Not all warranties 

are alike and Peak Scientific stand out against other gas suppliers as we offer a 
comprehensive, quick response, on-site warranty.  This means that in the very 

unlikely case that your gas generator develops a fault we have rapid support 
teams on-hand around the world who are able to come to your lab and get you 
back up and running in no time.

Register for your 

comprehensive 12 month on-site warranty 

with ease online at 

www.peakscientific.com/register.

Alternatively, you can send the completed form to Peak Scientific by post or 
email at [email protected].

Important!

You have 

1 month to register

 your Peak Scientific product from the date of 

installation. Once registered the warranty will be honoured for a period of 12 
months. If you wish to defer the installation of your generator, you must notify 
Peak Scientific immediately by emailing 

[email protected].

 For 

generators that remain unregistered after 1 month from the shipment date, the 
warranty will be considered active from the date of factory dispatch.

Содержание MS Table Series

Страница 1: ...MS Table Installation Guide Rev 1 PN IG 0012 21 09 16 MS Table All Models Installation Guide...

Страница 2: ...or more extensive user operation directions we recommend you download the User Manual from the website Please visit www peakscientific com downloads to download the full User Manual for your gas gener...

Страница 3: ...CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause damage to the Generator or the Application D...

Страница 4: ...ush Fit Fitting 02 4600 x1 UK Mains Cable C13 04 1028 x1 US Mains Cable C13 6 15 04 1029 x1 EU Mains Cable C13 04 1038 x1 US Mains Cable C13 5 15 04 1039 x6 M5 Plain Washer 00 1040 x6 M5 Spring Washer...

Страница 5: ...Page 5 Unpack the MS Table from the shipping crate and position on a flat surface in desired area 1 2 To lock the levelling feet in place firstly slacken off the 17mm top nut 0 0...

Страница 6: ...foot a further 1 full turn before tightening the locking nut to lock the foot in place For non gas versions of the MS Table proceed to step 8 or for instructions on fitting the optional water bottle m...

Страница 7: ...the water bottle mount locate the two mounting holes towards the back of the MS Table on the left side Using the screws and washers provided attach the water bottle mount in the order of Water bottle...

Страница 8: ...compressed air inlet bulkhead located at the rear of the unit 04 1028 04 1029 04 1038 04 1039 7 Select the appropriate mains cable from the fittings kit and plug the IEC 60320 C19 cable into the main...

Страница 9: ...60Hz OR 230VAC 50 60Hz Plug the mains cable into the corresponding 110VAC 50 60Hz OR 230VAC 50 60Hz single phase power supply CAUTION ensure the correct cable has been selected for your electrical sup...

Страница 10: ...Page 10 12 11 After 30 minutes of running the generator can be disconnected from the air supply The 6mm blanking plug can now be removed from the Drain port...

Страница 11: ...our instrument Re connect the compressed air supply to the Air inlet Connect 6mm PE Tubing 00 1282 to the Drain outlet Fit the other end of the tubing to a suitable drain connection or container The c...

Страница 12: ...Page 12 CONGRATULATIONS Your Peak Scientific MS Table is now fully installed operational and ready to supply gas on demand to your instrument 15...

Страница 13: ...stance away from the instrument the generator can be placed still using 6mm 4mm internal diameter or 3 16 internal diameter tubing is 10m For further information relating to tubing lengths please refe...

Страница 14: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Страница 15: ...or MS Table Installation Guide Rev 1 PN IG 0012 21 09 16 Peak Scientific has highly trained fully certified Field Service Engineers located in over 20 countries across every continent around the world...

Отзывы: