background image

WARNING

CAUTION

Page 5

WARNING

WARNING

WARNING

Safety Notices

Peak Scientific Instruments cannot anticipate every possible circumstance which may 

represent a potential hazard. The warnings detailed within this manual refer to the most 

likely potential hazards, but by definition cannot be all inclusive. If the user employs 

an operating procedure, item of equipment or a method of working which is not 

specifically recommended by Peak Scientific, the user must ensure that the equipment 

will not be damaged or become hazardous to persons or property.

Symbols

This manual uses the following symbols to highlight specific areas important to the safe 

and proper use of the generator.

A WARNING notice denotes a hazard. It calls attention to an operating procedure, 

process or similar, which if not correctly performed or adhered to, could cause 

personal injury or in the worst case death. Do not proceed beyond a WARNING 

notice until the indicated conditions are fully understood or met.

A CAUTION notice denotes a hazard. It calls attention to an operating procedure, 

process or similar, which if not correctly performed or adhered to, could cause 

damage to the generator or the application. Do not proceed beyond a CAUTION 

notice until the indicated conditions are fully understood or met. 

Caution, risk of electric shock. Ensure power to the generator has been removed 

before proceeding.

Safety Notice to Users

These instructions must be read thoroughly and understood before 

installation and operation of your Peak Generator. Use of the generator 

in a manner not specified by Peak Scientific MAY impair the SAFETY 

provided by the equipment. 

When handling, operating or carrying out any maintenance, personnel 

must employ safe engineering practices and observe all relevant local 

health and safety requirements and regulations. The attention of UK 

users is drawn to the Health and Safety at Work Act 1974, and the 

Institute of Electrical Engineers regulations.

If the equipment is used in a manner not specified by the manufacturer, 

the protection provided by the equipment maybe impaired.

Содержание Genius XE QSD

Страница 1: ...Genius XE QSD User Manual Rev 4 RSID 3490 EN 03 03 20 Genius XE QSD User Manual...

Страница 2: ...Environment 11 Generator Overview 12 General Dimensions 12 Genius XE QSD Rear Connections 13 Unit Controls 13 Drain Connection 14 Electrical Connection 15 Start Up Sequence 16 Connecting to the applic...

Страница 3: ...a reference document where you can skip to the relevant information Users can refer to the contents page to find the relevant information Please review each of the following sections carefully Thank...

Страница 4: ...ality of the foregoing that any defect is not the direct or indirect result of lack of repair and or servicing incorrect repair and or servicing use of wrong materials and or incorrect spare parts 2 A...

Страница 5: ...ted conditions are fully understood or met A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause...

Страница 6: ...nts for Electrical Equipment for Measurement Control and Laboratory Use Electromagnetic Compatibility Directive 2014 30 EU EN 61326 1 2013 Electrical Equipment for Measurement Control and Laboratory U...

Страница 7: ...th confirm that as a manufacturer of articles we conform to the European Parliament and Council Directives 2011 65 EU for the original 6 restricted substances listed in the Restriction of Hazardous Su...

Страница 8: ...f 3 hours before operation Generator Outlets Nitrogen Maximum Flow 16L min 5 52bar 0 57cfm 80psi Air Maximum Flow 67L min 7 58bar 2 37cfm 110psi Particles 0 01 m Phthalates NONE Suspended Liquids NONE...

Страница 9: ...e Peak Partner from where the unit was purchased Follow the unpacking instructions posted on the side of the crate It will require two people to remove the unit from the shipping crate and to manoeuvr...

Страница 10: ...gs Kit are as follows 1 Teflon Tubing x 3m x 3 2 6mm PE Tubing x 3m x 1 3 Compression Fitting x 3 4 6mm Push Fit Fitting x 1 5 Flow Control Silencer x 3 6 UK Mains Power Cable 230v x 1 7 EU Mains Powe...

Страница 11: ...ts These can sometimes give rise to pockets of air with high relative humidity Operation of the unit within such a pocket could adversely affect its performance Consideration should also be given to t...

Страница 12: ...2 Generator Overview General Dimensions The generator must always be placed on a flat level surface Failure to do so will affect the performance of the generator WARNING 570 mm 22 4 897 mm 35 3 700 mm...

Страница 13: ...and applications All Connections should only be carried out by trained personnel Generator must be switched off and unplugged prior to any cleaning or maintenance operations Unit Controls IEC Power I...

Страница 14: ...tubing to connect this to a suitable drain connection or container It should be noted that the Generator can expel a considerable amount of water from this dependant on ambient humidity If a containe...

Страница 15: ...nerator or risk overloading of the power cord This unit is classified as SAFETY CLASS 1 THIS UNIT MUST BE EARTHED Before connecting the unit to the mains supply please check the information on the ser...

Страница 16: ...is reached the compressors will continue to run until the internal tank upper pressure limit is reached and the compressor has run for a period of at least two minutes The compressors will then rest u...

Страница 17: ...leak in the gas supply between the generator and the application can lead to a reduction in efficiency Tubing Lengths The diameter of the tubing which will be connected to the gas outlets is importan...

Страница 18: ...erator is designed to operate in either a cyclic mode or run continuously this will be dependent on the output flow The cyclic rate of the compressors will depend on the gas demand of the application...

Страница 19: ...nths Genius XE QSD Annual Maintenance Kit www peakscientific com ordering 4 Years Genius XE QSD Year 4 Service Kit www peakscientific com ordering Please quote your generator serial number when orderi...

Страница 20: ...the LED on Stage 2 If the service is not completed the generator will continue to run After 2 weeks the service LED indicator yellow will start to flash This is to make the user aware that the service...

Страница 21: ...to install and setup your generator IQ OQ Certified assurance for applications requiring documented qualification Complete plan Swift response by a Peak Service Engineer within 72 hours planned preve...

Страница 22: ...e cloth prior to use Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator Under no circumstances should any solvents or abrasive cle...

Страница 23: ...ice provider The mass spec is reporting low pressure Contact your service provider Yellow SERVICE LED on front panel is on constantly A compressor s due for service Contact your service provider Refer...

Страница 24: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Страница 25: ...Page 25...

Страница 26: ...Page 26...

Страница 27: ...ustry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator cover and payment options speak to...