Page 9
Technical Specification
Genius SQ 24
Environment
Minimum Operating Ambient Temperature
5°C (41°F)
Maximum Operating Ambient Temperature
35°C (95°F)
Maximum Altitude
3000m
Maximum Relative Humidity
80% Non-Condensing
Minimum Storage Temperature*
-20°C (-4°F)
Maximum Storage Temperature*
60°C (140°F)
*NOTE – When taken out of storage the Generator should be allowed to acclimatize at room temperature
for a minimum of 3 hours before operation. Please ensure generator is in a well ventilated environment.
Generator Outlets
Maximum Gas Output Pressure
8 bar (116 psi)
Maximum Outlet Flow Rate**
24 L/min (0.85 cfm)
Particles
< 0.01 μm
Phthalates
NONE
Suspended Liquids
NONE
Gas Outlets
1 x 1/4" BSPP
Drain outlet
1 x 1/4” BSPP
Pressure gauges
1
** NOTE - Max Outlet Flow Rate @ 116 psi is 22 L/min (0.77 cfm)
Electrical Requirements
Voltage
230VAC
120VAC
100VAC
Frequency
50/60Hz
60Hz
50/60Hz
Current
6A
10A
11.2A
Input Connection
C20 Plug
Power Cord (Supplied)
C19 socket to local connection (13A minimum)
Pollution Degree
2
Installation Category
II
General
Dimensions mm (inches)
HxWxD
610 x 600 x 750 mm(24.0 x 23.6 x 29.5''
Generator Weight Kg (lbs)
83 Kg (183 lbs)
Shipping Weight Kg (lbs)
104 Kg (229.3 lbs)