background image

the strength of the wood studs is not sufficient, add reinforcement.  

Always confirm the center of the stud  is used for the installation.

 

 

Avoid installing in locations where the temperature and humidity are excessively high, and where contact with any  

 not install in locations where there are excessive amounts of dust, 

Do not block the ventilation holes.  Leave sufficient clearance in regard to the surroundings to avoid blocking the ventilation.

The internal temperature could elevate and possibly result in fire. Install the panel (4") or more away from surroundings.  

sloped surfaces. Also, do not install facing upward. The internal temperature could 

elevate and possibly result in fire. Injury or damage could also result from falling. 
Do not install in locations where there is excessive vibration or impact. Injury and damage could result from the panel display

light. Strong light could result in eye fatigue during usage. 

    

Use the specified bolts and screws in the specified places and tighten firmly. Failure to do this could cause injury if the panel 

 could result with injury due to the panel display falling. 

Always use at least two people to perform the installation work. Injury could result from dropping heavy objects. 

be installed must be capable of long-term support of the total load of  

so be taken to ensure sufficient strength to 

vibration and other external forces. 

panel display to fall and cause injury. 

MAXIMUM WEIGHT= 125 Lbs. ( 57 Kg.)

C a u t i o n :  I n s t a l l a t i o n  o f  u n i t  i s  t o  b e  c a r r i e d  o u t  b y  q u a l i f i e d  t e c h n i c i a n s  o n l y . I n s t a l l  i n  a n  a p p r o p r i a t e  

l o c a t i o n  b y  c h e c k i n g  t h e  w a l l  s t r u c t u r e  a n d  d u r a b i l i t y  f o r  s a f e t y  a n d   a c c i d e n t  p r e v e n t i o n .

 

 

          

INSTALLATION LOCATION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLATION ON A WOODEN WALL 

Always install so that the load is supported by a wood stud. If 
Do not install on decorative posts or plaster board.

 

 
 

 
         
 

          water is possible. These can result in fire or electric shock. 

Do not install close to an air conditioner intake or outlet. Do
oily smoke or tobacco smoke. Fire could result. 

          

Install only on a vertical surface. Avoid 

falling. 
Do not install where there is direct sunlight or other strong 

 
 
   
 

display falls. 
Do not alter any of the parts. Do not use broken parts. This

 

 

 
 
 
 

The wall where the wall mount is to 

the panel display and wall mount. Measures should al

withstand the force of earthquakes,

 

Note: 

Incorrect installation can cause the 

 

CAUTION

WARNING

WARNING

2

Total load ( panel d mount ) 

Rev 100708

Содержание AWM125-120

Страница 1: ...handling Please remember that if you remove the panel display from the wall later you will find the screw holes and anchor bolts for t mounting unit left on the wall Also note that long use of the panel display may discolor the wall around it due to its heat a airflow 1 Fig 1 All PDR mounts and adapters carry a limited lifetime warranty against defects in material and workmanship We are not liable...

Страница 2: ...work Injury could result from dropping heavy objects be installed must be capable of long term support of the total load of so be taken to ensure sufficient strength to vibration and other external forces panel display to fall and cause injury MAXIMUM WEIGHT 125 Lbs 57 Kg C a u t i o n I n s t a l l a t i o n o f u n i t i s t o b e c a r r i e d o u t b y q u a l i f i e d t e c h n i c i a n s o...

Страница 3: ...IRED PH M 06 40 00 M5 X 40 PAN HEAD PHILLIPS MACHINE SCREW 4 REQUIRED PH M 05 40 00 M8 X 16 PAN HEAD PHILLIPS MACHINE SCREW 4 REQUIRED PH M 08 16 00 M5 X 16 PAN HEAD PHILLIPS MACHINE SCREW 4 REQUIRED PH M 05 16 00 M6 X 16 PAN HEAD PHILLIPS MACHINE SCREW 4 REQUIRED PH M 06 16 00 32 ID X 75 OD X 1 00 LONG PLASTIC SPACER 4 REQUIRED SP E 32 10 01 M4 STEEL FLAT WASHER 4 REQUIRED FW M 04 09 00 PH M 04 1...

Страница 4: ...4 DRAWING SPECIFICATIONS Model AWM125 120 Single stud articulating wall mount 5 39 3 07 4 24 00 14 00 4 00 8 05 C L 4 67 20 7 15 DEG 5 DEG ...

Страница 5: ...sen the bottom bolt and set to a level position and re tighten the bolt 5 Pre drill and Install the center lag bolt and tighten SEE Fig 2 AWM125 120 item 11 and 12 1 Lay the display face down on a padded surface 2 Using the hardware supplied see page 3 attach the display bracket to the display SEE FIG 3 3 Check the depth of the mounting holes to assure you are using the proper length screws suppli...

Страница 6: ...Adjust by tightening the tension bolts to suit the desired freedom of movement See fig 6 1 Lift the tie holder 16 on the lock tab to allow access the bolt to adjust the tension on the arm center Replace the tie holder 16 after adjustment 3 Two other tension bolts can be tightened or loosened to suit SEE FIG 6 2 Adjust the tilt by loosening the Tri knob on the side of the AWM125 120 and adjust back...