Field Troubleshooting 

Troubleshooting involves determining the fault and then taking corrective 
action.  The fault is either external to the supply or a fault inside the supply.  
If the fault is internal (inside) the supply, remove from service and replace 
with a know good working central power supply. 

 

FAULT 

CORRECTIVE ACTION 

All TVs are dead. 

1.  Verify AC line voltage to the supply. 

 

2.  Power supply main circuit breaker tripped.  

Reset.  NOTE: A tripped main breaker indicates 
an overload condition and may require removing 
the power supply from service for further bench 
troubleshooting. 
 

3. 

Verify AC output voltage (28 VAC) at each “F” 
output fitting at the central power supply.  If an 
“F” output fitting is dead.  Reset the 
corresponding output circuit breaker if tripped.  If 
resetting the output circuit breaker does not clear 
the fault, remove the central power supply from 
service.  An internal fault has occurred that 
requires bench repair. 

 

 

Individual TV 
dead. 

1.  At the TV, open the cover on the support arm.  

Slide the rubber boot and expose the “F” barrel 
connec

tion.  Disconnect the “arm side” coax and 

verify AC voltage present on the supply side of 
the coax.  If AC power supply voltage (28 VAC) 
is present, a fault has occurred in the TV.  
Replace the TV. 

 
2.  At the central, check the corresponding output 

circuit breaker.  If tripped, reset the output circuit 
breaker.  NOTE: A tripped output circuit breaker 
may indicate either a TV or coax cable fault.   

 

 

Main circuit 
breaker will not 
reset. 

1.  Remove from service and replace with a know 

good working central power supply. 

 

 

 

Output circuit 
breaker will not 
reset. 

1. 

Disconnect the coax cable from the suspect ”F” 
output connector. Reset the output circuit 
breaker.  If the circuit breaker holds, a coax 
wiring or TV fault has occurred.   

 
2.  With the coax cable disconnected, reset the 

output circuit breaker.  If the circuit breaker trips 
an internal fault has occurred that requires bench 
repair.  Remove from service and replace with a 
know good working central power supply. 

 