background image

  

 

 
 
 
Better Solutions Are Within Reach

®

 

MODEL NUMBER:

 

PDI-772HE-IND 

Document Number:

 

PD196-181R3 

 

Individual Input Port Central Power Supply 

Page 1 of 12 

 

PDi Communication Systems, Inc.   40 Greenwood Lane   Springboro, Ohio 45066 USA   PH 1-800-628-9870  FX 937-743-5664  

 

 

 
WARNING

:  To reduce the risk of fire or electric 

shock, do not expose this apparatus to rain or 
moisture. 

 

WARNING: 

 To prevent injury, this apparatus must 

be securely attached to the wall in accordance with 
the installation instructions. 

 

WARNING:

  Do not install this equipment in a 

confined space such as a cabinet, drop ceiling, or 

similar space. 
 

CAUTION:

  Do not block ventilation openings,.  Install 

in accordance with the manufacturer’s instructions.

 

 
 

 

REGULATORY INFORMATION 

FCC PART 15 

This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to 
part 15 of the FCC Rules. 

These limits are designed to provide reasonable 

protection against harmful interference in a 
residential installation.  This equipment generates, 

uses, and can radiate radio frequency energy, and if 
not installed and used in accordance with the 

instructions, may cause harmful interference to radio 
communications. 

However, there is no guarantee that interference will 
not occur in a particular installation.  If this 

equipment does cause harmful interference to radio 
or television reception, which can be determined by 

turning the equipment off and on, the user is 
encouraged to try to correct the interference by one 

or more of the following measures:   

 

 

 
 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the 

equipment and receiver. 

 

Connect the equipment into an outlet on a 

circuit different from that to which the receive 

is connected. 

 

Consult the dealer or an experienced radio/TV 

technician for help. 

 

Modifications 

Any changes or modifications made to this device 

that are not expressly approved by PDi may void the 

user’s authority to operate the equipment.

 

 

Cables 

Connections to this device must be made with 

shielded cables with metallic RFI/EMI connector 
hoods to maintain compliance with FCC Rules and 

Regulations. 
 

Healthcare Grade Power Supply 

The PDi Healthcare series television is specifically 

designed for installation and use in a healthcare 
environment in which installation is limited to a 

nonhazardous area in accordance with the National 
Electrical Code, ANSI/NFPA70. 

 

 

 
 

 

 
 

 
 

 
 

 
 

 

Содержание PDI-772HE-IND

Страница 1: ...in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment...

Страница 2: ...t exhibits a distinct change n performance which indicated a need for service Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified...

Страница 3: ...It is not intended for mobile operation Do not use this product with a cart 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer allservicing to qualified...

Страница 4: ...set top satellite box a cable box or other similar RF device to be directed to one specific television Please refer to the schematic ACline voltage is stepped down using an isolation transformer inco...

Страница 5: ...ance betweenthe supply and furthest room to a maximum of 150feet Refer to the section titled CATV Wiring for coaxcable recommendations Cooling This power supply is engineered for high efficiency Pleas...

Страница 6: ...nt on a wall in an upright position with the power cord pointing down The supplyshould be positioned near an ACwall outlet This unit is convection cooled and requires clearance at the top bottom and s...

Страница 7: ...style coaxcable This style of coaxcan be easily confused with a pure copper coaxas the steelcenter conductor is platted with a copper cladding it looks likecopper Asa test touch a magnet to the cente...

Страница 8: ...binet and detach the ventilation cover exposing the RF F connector rows 3 Connect the RF signal cable from the satellite or set top box to the RF IN F connector Top Row Note Be sure the center conduct...

Страница 9: ...eeper and insert the IEC power cord plug into the ACjacklocated on the bottom of the power supply Press and seat the plug keeper onto the body of the plug 2 Now insert the ACpower cord plug into a pow...

Страница 10: ...s connected to the RFOUT F connector on the bottom row of the central power supply Wrong coaxcable used see CATV Wiring Poor reception or No Picture Station or CableCompany experiencing problems tune...

Страница 11: ...ifaffixed to any attachment not specified for the product 2 Product that has either the model number or serialnumber altered tampered with defacedor removed 3 Initial installation and removal for rep...

Страница 12: ...Reach MODEL NUMBER PDI 772HE IND Document Number PD196 181R3 Individual Input Port Central Power Supply Page 12 of 12 PDi Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 USA PH 1 80...

Отзывы: