User Manual for IP-PTZ643/645
67
Figure 5-45 Linkage Method
5.11.1 Configuring Alarm Output
Steps:
1. Enter the Alarm Output Settings interface:
Configuration>Advanced Configuration> Events > Alarm Output
2. Select one alarm output channel in the
Alarm Output
drop-down list.
3. Set a name in
for the
alarm output (optional).
4. The
Delay
time can be set to
5sec
,
10sec
,
30sec
,
1min
,
2min
,
5min, 10min
or
Manual.
The delay time refers to the time duration that the alarm output remains
in effect after alarm occurs.
5. Click
to enter the
Edit Schedule Time
interface. The time schedule
configuration is the same as the settings of the arming schedule for motion
detection. Refer to
Step 2 Set the Arming Schedule for Motion Detection
in
Section
5.9.1 Configuring Motion Detection
.
6. You can copy the settings to other alarm outputs.
7. Click
to save the settings.