10
1. Video Camera VC45
PCO
1999
VMC45-03/99
Remark
The Long Exposure Control can only be active when the module
is in the parallel mode
and
the shutter is off!
DIP switch S1/pin 7 = open
DIP switch S1/pin2 = closed; ENB don’t care
or
DIP switch S1/pin2 = open; ENB = low
EXPD
Long Exposure Power Down input
TTL level
For long integration times, the sensor can be set in a power-
down mode. This mode avoids the generating of an additional
dark current.
This input can be set parallel with the EXP input but must be re-
set at least 200ms before the EXP is reset.
The input is connected to a pull-up resistance.
Remark
The Long Exposure Power Down can only be active when the
module is in the parallel mode
and
the shutter is off!
DIP switch S1/pin 7 = open
DIP switch S1/pin2 = closed; ENB don’t care
or
DIP switch S1/pin2 = open; ENB = low
Содержание VC45
Страница 1: ...VC45 VC45 VM45 VM45 Operating Instructions Operating Instructions...
Страница 2: ......
Страница 4: ......
Страница 27: ...4 Appendix 27 PCO 1999 VMC45 03 99 Electrical Schematics of the board VMAIN...