background image

 

Section 7

 

EC Declaration of Conformity

 

E.M.C. STANDARD EN61326 CLASS A

 

We:  

Elect r o n ic  W eig h in g   Ser v ices  Lim it ed

 

Of:  

Lytton Street, Stoke on Trent. Staffordshire. ST4 2AG

 

Declare under our sole responsibility that the products: 

JUNI OR DWT 

EXCELSI OR DWT 

To which this declaration relates is in conformity with the following transposing 
harmonized standards:  

DI RECTI VE 

DESCRI PTI ON 

EN55022 

Radiated Emissions 

EN61000-4-4 

Fast Burst Transient  

EN61000-4-3 

Radiated I mmunity 

EN61000-4-6 

Conducted I mmunity 

EN61000-4-2 

Electrostatic Discharge 

2014/ 35/ EU 

Low Voltage Safety 

R.O.H.S  DI RECTI VE 

The instruments listed conform to the R.O.H.S directive and is therefore 
compliant with the directive. 

This declarat ion is made on the basis of certification and declarations provided to 
us from our component suppliers. Under our duty of due diligence these 
documents are stored for future audit purposes. 

Signed 

S.G. Keeling 

(Managing Director) 

Содержание Apex Junior

Страница 1: ...1 Apex Junior Cased Weighing Indicator Controller Document Version JG8 101215 Software Version H Board revision 1 4 onwards APPROVED DISTRIBUTORS OF Electronic Weighing Services USER MANUAL...

Страница 2: ...ve 6 26v d c E Ground ii DC Applications Battery Versions B Battery Positive B Battery Negative V Adaptor DC 12VDC V Adaptor Earth Suitable Charging Adaptor approx 12vdc 300mA minimum Correct Procedur...

Страница 3: ...t manual G8 WI NDHT 120603 02 1 2 3 4 5 6 DP K G 0A O D 02 Start 6 digits weight plus placed decimal point data MSD to LSD Units i e kg g or te 0A line feed 0D Carriage return D2 SETTI NG UP SERI AL C...

Страница 4: ...The display will briefly prompt LOAD and then indicate E00000 awaiting the input of your test load value at this point check that the platform is empty then enter your required test load value via th...

Страница 5: ...E key note the unit must have the necessary hardware options installed if printing or relay functions are selected Weigh Mode Print Mode Baud Select Line Feeds Function 0 Standard 0 Nett Kg 0 1200 0 1...

Страница 6: ...O and then MODE key together Release the ZERO key and then the MODE key 4 PEAK HOLD To select peak hold mode press the MODE key Peak weight will then be displayed until the MODE key is pressed again t...

Страница 7: ...ching operations from a loaded silo b One trip batcher mode MENU WEI GHMODE code 5 AUTOMATI C 5000x This mode controls a single relay continuously c Two trip batcher mode MENU WEI GHMODE code 6 AUTOMA...

Страница 8: ...ad cells Conversion 24bit Sigma Delta A D I nput Range 0 150mV Linearity 0 0015 F S Temperature Drift 2 p p m per degree C Update Speed 7ips or 30ips user selectable I nternal Resolution 300 000 count...

Страница 9: ...E DESCRIPTION EN55022 Radiated Emissions EN61000 4 4 Fast Burst Transient EN61000 4 3 Radiated Immunity EN61000 4 6 Conducted Immunity EN61000 4 2 Electrostatic Discharge 2014 35 EU Low Voltage Safety...

Отзывы: