background image

 

Section 5  

SPECI FI CATI ONS 

 

Display:

 6 digits, 18mm high LCD or LED displays 

Membrane:

 Polyester, tactile action. 

Enclosure:

 Splash proof, 165mm x 110mm x 60mm High Grade Stainless Steel. 

Operating Temperature:

 -10 to + 40 degrees C 

Load cell Capability:

 Up to 8 x 300R load cells 

Conversion:

 24bit Sigma Delta A-D. 

I nput Range:

 0 – 150mV  

Linearity:

 0.0015%  F.S. 

Temperature Drift:

 2 p.p.m per degree C 

Update Speed:

 7ips or 30ips – user selectable 

I nternal Resolution:

 300,000 counts for 10mV input (2mV per volt load cell) 

Calibration:

 Keyboard routine. 

Power ( Mains Option) :

 Mains version: 75-250vac 50/ 60Hz Auto Selection. 

Power ( D.C. Option) :

 6-26vdc 

Power Consumption

: LCD version operating 10mA, LED version operating 130mA. (add 16mA per 300R 

load cell) 

 

 

Содержание Apex Junior

Страница 1: ...1 Apex Junior Cased Weighing Indicator Controller Document Version JG8 101215 Software Version H Board revision 1 4 onwards APPROVED DISTRIBUTORS OF Electronic Weighing Services USER MANUAL...

Страница 2: ...ve 6 26v d c E Ground ii DC Applications Battery Versions B Battery Positive B Battery Negative V Adaptor DC 12VDC V Adaptor Earth Suitable Charging Adaptor approx 12vdc 300mA minimum Correct Procedur...

Страница 3: ...t manual G8 WI NDHT 120603 02 1 2 3 4 5 6 DP K G 0A O D 02 Start 6 digits weight plus placed decimal point data MSD to LSD Units i e kg g or te 0A line feed 0D Carriage return D2 SETTI NG UP SERI AL C...

Страница 4: ...The display will briefly prompt LOAD and then indicate E00000 awaiting the input of your test load value at this point check that the platform is empty then enter your required test load value via th...

Страница 5: ...E key note the unit must have the necessary hardware options installed if printing or relay functions are selected Weigh Mode Print Mode Baud Select Line Feeds Function 0 Standard 0 Nett Kg 0 1200 0 1...

Страница 6: ...O and then MODE key together Release the ZERO key and then the MODE key 4 PEAK HOLD To select peak hold mode press the MODE key Peak weight will then be displayed until the MODE key is pressed again t...

Страница 7: ...ching operations from a loaded silo b One trip batcher mode MENU WEI GHMODE code 5 AUTOMATI C 5000x This mode controls a single relay continuously c Two trip batcher mode MENU WEI GHMODE code 6 AUTOMA...

Страница 8: ...ad cells Conversion 24bit Sigma Delta A D I nput Range 0 150mV Linearity 0 0015 F S Temperature Drift 2 p p m per degree C Update Speed 7ips or 30ips user selectable I nternal Resolution 300 000 count...

Страница 9: ...E DESCRIPTION EN55022 Radiated Emissions EN61000 4 4 Fast Burst Transient EN61000 4 3 Radiated Immunity EN61000 4 6 Conducted Immunity EN61000 4 2 Electrostatic Discharge 2014 35 EU Low Voltage Safety...

Отзывы: