Operation Overview

Operation Overview

Upon power-up, the following 5 parameters are
displayed and updated automatically each second.

RH 

- The relative humidity sensor is located inside

the white plastic housing. The sensor may require a
longer period to stabilize in the event of extreme
humidity changes.

T

a

- The air temperature sensor is also located

inside the white plastic housing. 

T

s

- A surface temperature thermocouple is located

on the tip of the silver probe. It is spring loaded and
designed to quickly self-align on a surface. Press it
against a surface and allow a few seconds for the
value to stabilize.  Do not drag the sensor over the
surface. Wet the surface for a faster response.

For surface temperature measurement over

a long period of time, consider using the optional
Magnetic Surface Temperature kit (pg. 11).

T

d  

- The dew point temperature is a function of air

temperature and relative humidity (see ISO 8502-4
Annex A). It is the temperature to which a volume of
air must be cooled in order to reach saturation.

- The delta value is the surface minus dew point

temperature  (

T

s

T

d

). This value is important in

judging the risk of condensation, or dew, forming on
a surface.  For example, ISO 8502-4 recommends
that, unless otherwise agreed, the temperature of a
steel surface generally should be at least 3°C (5°F)
above the dew point when paints are applied.

The instrument may require a period of time

before the above climatic parameters stabilize. This
is most noticeable when the instrument is relocated
from one extreme environment to another (i.e. from
a warm location to a cold location). A period of up to
30 minutes should provide adequate time for
stabilization.

NOTE:

NOTE:

Содержание PT-DPM

Страница 1: ...561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton...

Страница 2: ...ccurately Measured parameters are Ta Air Temperature RH Relative Humidity Ts Surface Temperature Td Dew Point Temperature Surface minus Dew Point Power up Power down Power up Power down The PosiTector...

Страница 3: ...g period of time consider using the optional Magnetic Surface Temperature kit pg 11 Td The dew point temperature is a function of air temperature and relative humidity see ISO 8502 4 Annex A It is the...

Страница 4: ...rt TrendTM Indicators identify rising falling or stable readings The instrument compares each measurement with the average of recent values in an attempt to provide the current direction of change Whi...

Страница 5: ...ress to scroll DOWN to scroll UP and to SELECT Press both buttons at any time to exit any menu or select Exit from the Menu List boxes have a down arrow on the right hand side Use the and buttons unti...

Страница 6: ...ement The PosiTector DPM can record 2 500 datasets in up to 100 groups batches for on screen analysis for printing to an optional IR printer or for downloading to a personal computer using optional Po...

Страница 7: ...ss or button to view batch statistics and individual datasets see Figure 2 Figure 1 lists all datasets beginning with the current or most recently used batch Open selects a previously created batch na...

Страница 8: ...buttons Press to select the element in focus then select OK The instrument will display the Auto Log symbol and will begin recording An audible tick sound will emit from the instrument every few secon...

Страница 9: ...red into the currently opened batch If no batch is open a new batch will be created Datasets are recorded regardless of the state of the Smart Trend Indicators see pg 4 To turn off Auto Log press the...

Страница 10: ...llowing occurs all batches are closed and stored datasets are erased menu settings are returned to the following Memory OFF Alarm ON A more thorough Reset can be performed by holding the button when t...

Страница 11: ...umidity sensor and a K type connector that accepts the magnetic surface temperature probe Magnetic surface temperature probe with armored cable and locking device to prevent accidental disconnection f...

Страница 12: ...analysis software Downloads stored datasets to a PC with included USB cable Allows entry of notes and annotations prints histograms and basic charts manages data and datasets can be exported to a doc...

Страница 13: ...obe to stabilize 30 minutes for a change of RH greater than 50 It may take longer if the probe was left at low RH for several months To increase response time soak the sensor in a damp face cloth over...

Страница 14: ...ce the batteries after the instru ment has automatically powered down Nickel cadmium and nickel metal hydride recharge able batteries will work but the instrument may appear to have weak batteries Cha...

Страница 15: ...ment body Dimensions 178 x 64 x 31 mm 7 x 2 5 x 1 2 Weight 185g 6 5 oz without batteries Battery Life 100 hours continuous 80 hours Auto Log Returning for Service Returning for Service Before returnin...

Страница 16: ...rrors 16 Limited W Limited Warranty arranty Sole Remedy Sole Remedy and Limited Liability and Limited Liability DeFelsko s sole warranty remedy and liability are the express limited warranty remedy an...

Отзывы: