Phase measurement connection (L1, L2, L3, N, PE)
Further meters can be connected via these laboratory plug connections in order to carry out
measurements. This terminal is directly connected to the charging station.
Note:
This terminal is for measurement only and must not be used for charging.
9
Maintenance
No special maintenance is required for the tester. If any problems occur, the customer service
must be informed.
9.1
Cleaning
After use, the tester must be cleaned. Use a dry cloth and a mild household cleaning agent for
this purpose. No aggressive cleaning agents should be used. Before cleaning, all cables must be
disconnected from the tester. After cleaning, the meter may be used as soon as it is completely
dry.
9.2
Transport and storage
For transport and storage, the transport bag should be used to prevent damage. During storage,
ensure that the tester is stored in a dry environment. If the tester is exposed to extreme
temperatures during transport, it must first acclimatise for two hours.
9.3
Replace fuse
If the fuse blows, it must be replaced. To do so, the tester must be disconnected from all lines.
Ensure that there is no voltage. Then open the compartment for the fuse on the back and replace
it by a 10 A (H) 250 V, 5 x 20 mm fuse. You can then close the compartment. The tester is now
ready for use again.