background image

Manual 

12 

6.2 

Time setting 

Here you can set the time (“Set time”), date (“Set date”) and how time and date are displayed (“Time 
format” / “Date format”). Select the desired option by using the arrow keys (

 and 

) and press Enter 

 to confirm. 

 

Set time / date 

Here you can set the individual digits of the time and date. Adjust the selected digit by using the arrow 

keys (

 and 

) and press Enter 

 to get to the next digit. After confirming the last digit by pressing 

Enter 

, the time / date is set. 

 
Time format 

Here you can choose between 24 h format and 12 h format. Use the arrow keys (

 and 

) for selection 

and press Enter 

 to confirm. 

 

Date format 

Here you can choose between year-month-day, month-day-year and day-month-year. Use the arrow keys 

(

 and 

) for selection and press Enter 

 to confirm. 

6.3 

Print settings 

Here you can choose if the measurement results are printed automatically or not when a printer is 

connected to the colorimeter. Choose the desired option by using the arrow keys (

 and 

) and press 

Enter 

 to confirm. If automatic printing is turned off, you can print the data by pressing and holding the 

Up/Print button 

6.4 

Backlight time 

Here you can choose how long the backlighting shall be active. Choose the desired option by using the 

arrow keys (

 and 

) and press Enter 

 to confirm. 

6.5 

Brightness setting 

Here you can adjust the brightness of the display. Use the arrow keys (

 and 

) to select an option and 

press Enter 

 to confirm. 

6.6 

Battery capacity 

Here you can check the battery status. 

6.7 

Restore factory 

Here you can restore the factory settings. To do so, press Enter 

 in the confirmation screen. Press 

Back 

 to cancel. 

 

 

Содержание PCE-CSM 3

Страница 1: ...ter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Busines...

Страница 2: ...PC or printer 10 5 3 4 Tolerances 10 5 3 5 Delete recorded data 10 5 3 6 Averaging 10 5 3 7 Display mode 11 5 3 8 Language 11 6 Settings 11 6 1 Auto save 11 6 2 Time setting 12 6 3 Print settings 12...

Страница 3: ...suring device Please avoid strong changes in the environmental conditions This includes flickering lights as well as changes of the air temperature or air humidity The device may only be used in the a...

Страница 4: ...Lamp life 3 years more than 1 million measurements Storage 100 reference values standards 20 000 samples Interface USB RS 232 Power supply Rechargeable lithium ion battery 3 7 V at 3 200 mAh Charging...

Страница 5: ...Manual 5 4 System description 4 1 Button description 4 2 Interfaces...

Страница 6: ...USB interface you can transfer data from the colorimeter to a PC The baud rate is 115 200 bps 4 3 Battery Installing the battery 1 Make sure that the colorimeter is turned off 2 Open the cover of the...

Страница 7: ...easuring mode is L a b C h 5 2 Take a measurement If you turn on the device you are directed to the Standard Measurement screen To take a measurement follow these steps 1 Press and hold the testing bu...

Страница 8: ...took the standard measurement 3 Now you can see the results and the deviation to the standard in the following screen Note While the measurement is in progress time duration 1 second all buttons are i...

Страница 9: ...ation To get to the calibration menu press the Menu button select Calibrate and press Enter Here you can select between white and black calibration Use the arrow keys and to select and press Enter to...

Страница 10: ...ta To delete the recorded data press the Menu button select Delete and press Enter Now you get to the deletion screen Here you have two different options You can either delete all sample measurements...

Страница 11: ...nguage and press Enter Now you get to the language selection You can choose between English and Chinese Select an option by using the arrow keys and and press Enter to confirm 6 Settings To get to the...

Страница 12: ...he arrow keys and for selection and press Enter to confirm 6 3 Print settings Here you can choose if the measurement results are printed automatically or not when a printer is connected to the colorim...

Страница 13: ...alibration After that perform a black calibration 2 Fill in the powder Fill the powder into the powder compartment of the measuring plate After that put the powder test box back together see 7 1 1 Mak...

Страница 14: ...u can determine the colorimetric parameters of liquids pastes and powders 7 2 1 Build up The PCE CSM UTC is built up of a base plate 1 an alignment plate for the colorimeter 2 a measuring chamber 3 wi...

Страница 15: ...e measuring hole of the measuring chamber 3 Make sure that the colorimeter is in the right place and tightened properly before moving on 2 Fill the tank 4 with the desired medium and put it into the m...

Страница 16: ...mber Please make sure that these indications are aligned properly see picture below 4 Perform a measurement with the colorimeter 5 Clean the measuring device before each use Do not use abrasive or cor...

Страница 17: ...contact PCE Instruments 8 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 8 2...

Отзывы: