background image

 

 

©  PCE Instruments 

 

Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Содержание PCE-AMM 5

Страница 1: ...logue Multimeter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Страница 2: ...evice Layout 4 5 Display Layout 5 6 Measuring procedure 5 6 1 DC Voltage Measurement DCV 5 6 2 AC Voltage Measurement ACV 6 6 3 Current Measurement DC mA 7 6 4 Resistance measurement 7 6 5 LED Measure...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...sistance Measuring Range Accuracy Central value 2 k RX1 3 20 20 k RX10 3 20 200 k RX100 3 20 2 M RX1k 3 20 20 M RX10k 3 20 More Specifications Measurement Functions ACV DCV DCA dB continuity test diod...

Страница 5: ...another symbol or a connection and is a reference to the user manual This icon indicates that high voltage could be present Shock hazard Double insulation Earth ground DC direct current AC alternatin...

Страница 6: ...PCE Instruments 4 4 Device Layout 1 Protective cover 5 Resistance Zero Point Test 2 Display Cover 6 Function Dial 3 Pointer 7 Panel 4 Manual Pointer Adjust 8 Input Jacks 1 2 3 4 5 6 7 8...

Страница 7: ...dangerous voltage The operator should read the manual carefully before use and always keep his her finders behind the ring guard when measuring 6 1 DC Voltage Measurement DCV Switch the device to DCV...

Страница 8: ...AC Voltage Measurement ACV Switch the device to ACV range Insert the test leads as shown in the figure below Select the appropriate voltage in the function dial 6 Measure the voltage and read the res...

Страница 9: ...scale 13 6 4 Resistance measurement Warning When measuring resistance make sure that the power of the circuit under test is turned off and all capacitors are powered off before testing Otherwise there...

Страница 10: ...LED and read the result on the DC mA scale 13 LI reads the positive current LV reads the positive voltage 6 6 Continuity Test Switch the device to x1 range Adjust the pointer manually to zero 4 Insert...

Страница 11: ...capacity of 0 1uF and a withstand voltage greater than 500 should be connected in series Switch the device to 10V on the ACV range Measure the dB and read the result on the dB scale 14 The dB scale sh...

Страница 12: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 13: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...

Отзывы: