Function 

 

Description page 2 

 
 
 
 

 

Capture Length 

You can set a value between 1 and 1280 seconds. This value 
represents the duration of curve capturing in capture mode which 
depends on the sampling rate: 

 

Sampling rate 6 Hz: 1 ~ 1280 seconds 
Sampling rate 12 Hz: 1 ~ 640 seconds 
Sampling rate 25 Hz: 1 ~ 320 seconds 
Sampling rate 50 Hz: 1 ~ 160 seconds 
Sampling rate 100 Hz: 1 ~ 80 seconds 
Sampling rate 200 Hz: 1 ~ 40 seconds 
Sampling rate 400 Hz: 1 ~ 20 seconds 
Sampling rate 800 Hz: 1 ~ 10 seconds 
Sampling rate 1600 Hz: 1 ~ 5 seconds 

 
 

 

F/P Boundary 

You can set a value between 1 and 99999. This setting is used during 
peak value measurement to determine the first peak value. When you 
press the Arrow Right key, a new peak value measurement will start. 
Meanwhile, the values peak-to-peak (Vmax), valley-to-peak (Vmin) 
and new peak (Vnew) are updated continuously. For example, if 10 is 
set as the criterion, Vmax or Vmin will be counted as the first peak 
value when the absolute value of (Vmax - Vnew) or (Vmin - Vnew) is 
above 10. 

 
 
 
 
 
 

 

Serial Port 

This port is used to control the real-time data transfer. The following 
parameters can be set: 

 

Prohibit: The real-time data transfer of the serial interface is 
prohibited. 

 

Key/Order: A single output will take place when you press the Up key 
or when an output command is received. When the force gauge is 
connected to a computer, the programmes on the computer will 
automatically disable the output function. 

 

Change: A single output will take place when the measuring data 
change. 

Stabilize: A single output will take place when the reading stabilises. 

Consecutive: The measuring data are transferred without interruption. 

 

Auto Power Off 

This function reduces the energy consumption. The force gauge will 
automatically power off when it has not been used for a certain period 
of time. 

Max Charge V 

This window shows the maximum voltage of the battery. 

 

Clear Storage 

Here, you can delete saved measurement reports and curves. 

 

Important information: 

When the memory is full, all data will automatically be deleted to 
enable new data to be saved. 

Factory Test 

Only relevant for customer service. 

S/N 

This window shows the serial number of the device which cannot be 
changed. 

Capture Trigger 

Here, you can set a value between -99999 and +99999. The range of 
values depends on the set unit. This parameter stipulates the 

 

E

n

g

li

s

h

 

Содержание CAL-PCE-DFG N

Страница 1: ...is taliano espa ol portugu s nederlands t rk polski can be downloaded here www pce instruments com Son de i iklik last change 3 March 2021 V 1 5 i Dinamometre Digital Force Gauge PCE DFG N Serisi Kull...

Страница 2: ...2 Teslimat eri i 3 2 3 Opsiyonel Aksesuarlar 4 3 Sistem A klamas 5 3 1 Cihaz 5 3 2 Aray z 5 3 3 Ekran 6 3 4 Fonksiyon tu lar 7 4 Kullan ma Haz rl k 7 4 1 G kayna 7 4 2 Ayarlar 8 5 Kullan m 12 5 1 l m...

Страница 3: ...contents 17 2 3 Optional accessories 18 3 System description 19 3 1 Device 19 3 2 Interfaces 19 3 3 Display 20 3 4 Function keys 21 4 Getting started 21 4 1 Power supply 21 4 2 Settings 22 5 Operatio...

Страница 4: ...cihaz n l lebilir maksimum de eri uygulanan darbe y k n n iki kat kadar olmal d r Darbe testleri ger ekle tirirken yaralanmalar n n ne ge mek i in maske ve koruyucu eldiven giyilmelidir Test stand b...

Страница 5: ...G N 10 PCE DFG N 20 PCE DFG N 200 PCE DFG N 500 l m Aral 0 5 N 0 10 N 0 20 N 0 200 N 0 500 N z n rl k 0 001 N 0 002 N 0 005 N 0 01 N 0 05 N Boyut 200 x 97 x 42 mm A rl k Yakla k 540g Harici l m h crel...

Страница 6: ...ar 10 50 C 5 95 n o yo u mas z Koruma S n f IP 54 2 2 Teslimat eri i Dahili h creli versiyon Harici h creli versiyon 1 x Dinamometre PCE DFG N 5 x l m Ucu Adapt rleri Sivri Kafa Adapt r entikli Kafa A...

Страница 7: ...N set 2 par a PCE C A 2500N EB G zl civata M12 2 500 N set 2 par a PCE C A 5000N EB G zl civata M12 5 000 N set 2 par a PCE C A 10000N EB G zl civata M12 10 000 N set 2 par a PCE C A 60KN EB G zl civ...

Страница 8: ...i h creli versiyon 1 l m mili 6 Sivri kafa adapt r 2 Ekran 7 Kanca adapt r 3 Klavye 8 entikli kafa adapt r 4 Uzatma ubu u 9 D z kafa adapt r 5 Keski kafa adapt r 10 Uzatma ubu u i in adapt r 3 2 Aray...

Страница 9: ...rici giri k anahtar 2 k alt s n r 3 k st s n r 4 GND topraklama 1 Haf za kullan m 7 Pil seviyesi g stergesi 2 l m e risi 8 Ayarlanm rnekleme h z 3 Kuvvet de eri 9 Alt alarm de eri 4 st alarm de eri 10...

Страница 10: ...naylama Sol E ri kayd na ba lama E ri kayd na ba lama Yan p s nen say y bir basamak sola ta ma Sa Peak de erini silme Peak de erini silme Yan p s nen say y bir basamak sa a ta ma 4 Kullan ma Haz rl k...

Страница 11: ...r S f r Noktas Zero Tracking S f r noktas i in a a daki de erler ayarlanabilir Kapal 0 1 N 0 2 N 0 3 N 0 4 N 0 5 N S f r noktas stabilizasyonundan nce ayarlanan de erin alt ndaki de erler otomatik ola...

Страница 12: ...girmek Kullan c kaydedilen kalibrasyon verilerini girer Kalibrasyon herhangi bir cihaz ya da a rl k olmadan yap l r 2 Standart kalibrasyon Cihaz kalibrasyon stand ya da kalibrasyon a rl arac l yla kal...

Страница 13: ...m engellenir Tu Komut Yukar tu una bast n zda ya da k komutu al nd nda bir kez k ger ekle ir Cihaz bilgisayara ba land nda bilgisayardaki programlar k fonksiyonunu otomatik olarak devre d b rak r De i...

Страница 14: ...ri bilgisayara aktar m s ras nda kaybolur l m sonu lar cihaz n i inde kal r G r nt leme A s Display Angle Burada g r nt leme a s n ayarlayabilirsiniz 0 ya da 180 i se ebilirsiniz Otomatik Arka Ayd nla...

Страница 15: ...iyi ve kay t s resini ayarlay n l m moduna geri d nmek i in Geri tu una bas n l me ba lamak i in cihaz uygun test stand na yerle tirin S f r ve sa ok tu una bas n Do rudan l m ger ekle tirebilir ya da...

Страница 16: ...m H1 mm M mm A rl k 1 kN 50 8 76 2 20 8 15 3 M10 x 1 5 540 g 2 5 5 kN 50 8 76 2 20 8 13 6 M12 x 1 75 540 g 10 kN 50 8 76 2 27 2 12 1 M12 x 1 75 680 g 20 50 kN 76 2 101 6 27 2 20 M20 x 1 5 1350 g 100 k...

Страница 17: ...bilgilendirmek zorunday z Kullan lm piller evsel at k olarak at lmamal d r T keticiler pilleri t ketici i in cretsiz olan uygun bir ticari veya belediye toplama noktas na vermekle y k ml d r Kullan lm...

Страница 18: ...TION For impact tests the maximum measurable value of the force gauge should be twice as high as the applied impact load When doing impact tests wear a mask and protective gloves to avoid injuries Do...

Страница 19: ...PCE DFG N 10 PCE DFG N 20 PCE DFG N 200 PCE DFG N 500 Range 0 5 N 0 10 N 0 20 N 0 200 N 0 500 N Resolution 0 001 N 0 002 N 0 005 N 0 01 N 0 05 N Accuracy Dimensions 200 x 97 x 42 mm Weight approx 540...

Страница 20: ...Output port 12 V 50 mA Operating conditions 10 50 C 5 95 RH non condensing Protection class IP 54 2 2 Delivery contents Version with internal cell 1 x force gauge PCE DFG N 5 x test head adaptors poin...

Страница 21: ...set 2 pieces PCE C A 5000N EB eyebolt M12 5 000 N set 2 pieces PCE C A 10000N EB eyebolt M12 10 000 N set 2 pieces PCE C A 60KN EB eyebolt M20 60 000 N 6 t set 2 pieces PCE C A 120KN EB eyebolt M30 12...

Страница 22: ...metric cell 1 Measuring shaft 6 Pointed head adaptor 2 Display 7 Hook adaptor 3 Keypad 8 Notched head adaptor 4 Extension rod 9 Flat head adaptor 5 Chisel head adaptor 10 Adaptor for extension rod 3 2...

Страница 23: ...t 2 Output lower limit 3 Output upper limit 4 GND 3 3 Display In measurement mode 1 memory usage 7 battery level indicator 2 measurement curve 8 set sampling rate 3 force value 9 lower alam value 4 up...

Страница 24: ...e capturin g Move flashing number left by one digit Right Delete value peak Delete peak value Move flashing number right by one digit 4 Getting started 4 1 Power supply The PCE DFG N is equipped with...

Страница 25: ...set Off 0 1 N 0 2 N 0 3 N 0 4 N 0 5 N Values below the value set are automatically excluded before the zero point stabilises After stabilisation of the reading the sampling rate will be 1 x per second...

Страница 26: ...d calibration The force gauge is calibrated by means of the calibration stand or calibration weight User Gravity Here you can set the gravity at the place of use The value can be between 9 700 and 9 9...

Страница 27: ...ata transfer The following parameters can be set Prohibit The real time data transfer of the serial interface is prohibited Key Order A single output will take place when you press the Up key or when...

Страница 28: ...00 bps 1600 Hz 230400 bps Due to the limited speed of serial interfaces some data get lost when transferred to a PC if the sampling rate is higher than 800 Hz The readings will however not get lost in...

Страница 29: ...ure trigger as well as the capture length duration Press the Back key to return to measurement mode To start your measurement attach the device to a suitable test stand Press the Zero key and the Arro...

Страница 30: ...nents 7 Appendix load cell 1 100 kN L mm H mm W1 mm H1 mm M mm 1 kN 50 8 76 2 20 8 15 3 M10 x 1 5 2 5 5 kN 20 8 76 2 20 8 13 6 M12 x 1 75 10 kN 50 8 76 2 27 2 12 1 M12 x 1 75 20 50 kN 76 2 101 6 27 2...

Страница 31: ...lutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devices b...

Страница 32: ...Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 05...

Страница 33: ...ts 30 PCE Instruments Specifications are subject to change without notice User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be downloaded here www pce in...

Отзывы: