9-2 Troubleshooting
C o m m o n E r r o r s
This section lists the most common errors you may see. Call Technical
Support if you receive any error not listed here.
Error
Description/Action
025
String length is outside the range
0
to
2710
.
101
The format referenced by batch is not in memory.
409
The printer memory is full. Delete unnecessary formats or
graphics from memory.
410
Parity mismatch.
411
Framing error (baud rate mismatch).
412
Flow control mismatch.
413
Online receive queue is full. Check for a flow control problem.
611
Font, bar code, or density in the batch does not exist.
612
The data in this line of the batch is either missing or does not
match the format.
613
Reference point off supply.
614
Portion of field off supply or there may be an invalid character in
the packet.
703
The printer sensed a calibration of different-sized black marks.
Make sure the correct supply is loaded.
704
Printer has not sensed a supply mark within the specified number
of inches or out of supplies. Check the supply tracking, supply
marks, black mark sensor position, and supply roll for binding.
Press
CANCEL
. Change supply.
750
Printhead is overheated. Turn off the printer.
Содержание 9856
Страница 12: ...1 8 Getting Started ...
Страница 42: ...7 4 Care and Maintenance ...
Страница 48: ...9 4 Troubleshooting ...
Страница 51: ...www monarch marking com ...