24
99B138120x-mub-en | 2014/11 | V05
EN
8.2
Calling up the settings menu and selecting a menu
entry
√
Automatic
or
Off mode
is selected.
1. Press and hold
SET
for two seconds. The settings menu is displayed, menu entry
flashes.
2. Press
to select a different menu entry.
3. Change the settings as described in the following sections.
8.3
Setting the time
√
flashes.
1. Press
SET
. The hour flashes.
2. Press
to set the hours.
3. Press
SET
. The minutes flash.
4. Press
to set the minutes.
5. Press
SET
.
6. Repeat the steps 4 and 5 in order to set the year, the month and the day.
8.4
Setting the functions
√
F
unc
flashes.
X
Continue as described in the
Functions
section.
8.5
Set nominal temperature of the domestic hot water
Functioning
The controller attempts to regulate the domestic hot water temperature to the value that
has been set.
The domestic hot water temperature can be changed within the following limits.
Minimum:
20 °C
Maximum:
90 °C
Factory setting: 60 °C
Operation
√
P
ara
flashes.
1. Press
SET
. The nominal temperature of the
domestic hot water is displayed, the
corresponding component in the system
graphics is flashing (fig. left).
2. Press
SET
. The temperature value flashes.
3. Press
, to change the value.
4. Press
SE
T, the change is set.
Advice for comfort optimisation:
For high buffer tank temperatures (f.ex solar thermal system) the domestic hot water
temperature must be set as high as possible (max. 60 °C).