13 Setting for Recirculation
Auto recirculation (Learning mode) start
automatically when the Remote Controller is turned
on. When changing other recirculation mode (e.g.
conforming to Title 24), change the setting as
follows.
For RC-7651M-A
1. Turn the Water Heater off by pressing the
button on the Remote Controller.
2. Disconnect, then reconnect the electrical power
to the Water Heater.
For RC-9018M
1. Turn the Water Heater off by pressing the
“Power” button on the Remote Controller.
2. Disconnect, then reconnect the electrical power
to the Water Heater.
NOTE
The setting must be done within the
first 10 minutes of connecting the
electrical power to the Water Heater.
NOTE
The setting must be done within the
first 10 minutes of connecting the
electrical power to the Water Heater.
NOTE
• The setting changes can be
cancelled by pressing the button
before confirming the settings, or
if the Water Heater is left alone for
10 minutes without confirming the
settings.
• If the default setting needs to be
changed again, disconnect the
electrical power to the Water
Heater, reconnect it and repeat this
procedure.
3. Press the button and hold it until the Remote
Controller displays item number “99”.
• This will put the Water Heater into
Maintenance Writer mode.
• If pressing the button does not put the
Water Heater into Maintenance Writer mode,
make sure the remote controller display
is blank, unplug the Water Heater for 60
seconds, and try again.
4. Change the Maintenance Writer item number
display using the / buttons, and then press
the button for 0.5 seconds.
• The item number setting change from “OFF”
to “ON”.
• If the PRIORITY indicator turns on when an
item number is displayed, this indicates an
“ON” setting for that item number, and if the
PRIORITY indicator is off, the item number is
“OFF”.
5. After setting these item number, press and
hold both the / buttons for five seconds to
confirm the new settings.
• The Remote Controller will emit a beeping
tone and the display will go blank when the
settings are confirmed.
• If this is not done, the Water Heater will not
put the setting changes into effect.
3. Press the / buttons and hold them until the
Remote Controller displays item number “99”.
• This will put the Water Heater into
Maintenance Writer mode.
• If pressing the / buttons does not put the
unit into Maintenance Writer mode, make
sure the remote controller display is blank,
unplug the Water Heater for 60 seconds, and
try again.
4. Change the item number on the column of the
item using the / buttons, and then press
the “ENTER” button.
• “Item number” stops blinking and “Date state
(OFF or ON)” will start blink.
5. Change from “OFF” to “ON” using the /
buttons, and then press the “ENTER” button.
• “Data state (ON)” stops blinking and “Item
number” will start blink.
6. After setting these item number, press and
hold both the / buttons until the Remote
Controller will emit a beeping tone.
• If this is not done, the Water Heater will not
put the setting changes into effect.
7. Disconnect the electrical power to the Water
Heater.
Wait 10 seconds or more, and reconnect the
electrical power.
Item #
3B 24
23
22
Auto Recirc (Default)
OFF OFF OFF OFF
On-Demand (Title 24) Mode ON OFF ON ON
Manual Timer Recirc*
OFF ON OFF ON
Always Recirc ON
OFF OFF ON OFF
Always Recirc OFF
OFF OFF ON ON
Item #
3B 24
23
22
Auto Recirc (Default)
OFF OFF OFF OFF
On-Demand (Title 24) Mode ON OFF ON ON
Always Recirc ON
OFF OFF ON OFF
Always Recirc OFF
OFF OFF ON ON
* If the water heater will not be used for a long
period of time at the “Manual Timer Recirculation”,
turn off the recirculation program for energy
saving. The procedure to turn off is shown in the
User’s Manual (RC-9018M) on page 17.