![Pavilion GQ-C3260WXQ-FF PB US Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/pavilion/gq-c3260wxq-ff-pb-us/gq-c3260wxq-ff-pb-us_installation-manual_763984050.webp)
50
10.3 Recirculation
Connecting the on-demand switch
1. Leave enough slack so that the on-demand
switch wires will stay connected if the Water
Heater is removed from the wall.
2. Check the electrical power is disconnected from
the Water Heater.
3. Remove the front cover (4 screws).
4. Connect the on-demand switch wires to On-
demand SW terminal in the Water Heater.
2.7 mA @ 15 VDC will be applied to the on-
demand switch.
5. When installing wireless on-demand switch or
motion sensor, use a relay and connect to make
contact (Normally Open Contact).
6. Reattach the front cover (4 screws).
10.3.1 On-demand Switch
• Install the on-demand switch if necessary or when
conforming to California Code of Regulations Title
24 Part 6.
• This Water Heater is compatible with on-demand
switch, wireless switch and motion sensor.
• Prepare a relay when installing wireless on-
demand switch or motion sensor. Do not apply
any voltage to the On-demand SW terminal. This
terminal is only for No-voltage contact.
Contact Rating: more than 2.7 mA @ 15 VDC.
• (For Quick Connect Multi-System)
Connect the on-demand switch to the Water
Heater connected with Remote Controller.
1. Leave enough slack so that the thermostat
wires will stay connected if the Water Heater is
removed from the wall.
2. Check the electrical power is disconnected from
the Water Heater.
3. Remove the front cover (4 screws).
10.3.2 Thermo-sensor (Thermostat)
• Install the thermostat and adjust the setting in
accordance with Title 24.
• (For Quick Connect Multi-System)
Connect the thermostat both of the Water
Heaters.
120 VAC
2
4
0
1
Connect to
on-demand switch
wires in Water Heater
Relay
(e.g. Omron G7L2ABUBJCBAC120)
On-demand SW
Receiver of wireless
on-demand switch or
motion sensor output
Use a relay when connecting wireless switch or
motion sensor
1. Refer to the step 1 - 3 of “Connecting the on-
demand switch”.
2. Choose a suitable installation location for the
relay where it will be protected from moisture.
3. Connect the on-demand switch wires from the
heater to the signal output on the relay.
4. Cut one of the electrical supply leads and
connect to the signal input on the relay.
5. Secure all connections and reattach the front
cover.
On-demand SW
Wire Tag
Crimping
Terminal
To the on-demand switch
(Use a relay for wireless
on-demand switch or
motion sensor)
Wiring
Throughway
Circuit Board
3. Open the external remote terminal block.
4. Pass the Remote Controller Cord through the
wiring throughway.
Connect the Y-shaped terminals at the end of
the Remote Controller Cord to the terminal
block.
5. Reattach the terminal block cover.
NOTE
Tie the redundant cord outside the
Water Heater. Do not put the extra
length inside the Water Heater.
1) Pinch
2) Pull downward
Wiring Throughway
Remote Controller Cord
Connecting Electricity
Содержание GQ-C3260WXQ-FF PB US