LIMITED WARRANTY

Paulin Products, Inc., as Manufacturer, warrants its indoor gaslights to the ORIGINAL
PURCHASER only and only to the extend and conditions below:

1.  For a period of the earlier of thirty (30) days after purchase or one (1) year after date of
manufacture (date is metal stamped on Wall Plate), at Manufacturer’s option, will repair or
replace any parts EXCEPT glass parts, gaskets, or mantles found under normal use to be
defective in factory materials or workmanship.

2.  This warranty will apply and the repair or replacement will be made without charge, only if:

a. The unit is used in an unaltered form and assembly and only indoors and only for

              appropriate illumination purposes.

b. The unit is used with propane gas (model 9 or 9T) or butane gas (model 9B or 9BT)
    only in a well ventilated area.
c.  The unit shall not have been installed or serviced by anyone other than by a
    qualified gas service personnel.
d.  The unit shall have been installed, operated and maintained in accordance with
     the instructions and purchaser shall have read and heeded the warnings
     regarding use.
e.  The unit shall be shipped (less globe) to Paulin Products, Inc. at the address below,
     freight prepaid, accompanied by a letter stating service or repairs desired.
     Be sure to give full information, including date and place of purchase, full name
     and address.

3.  Manufacturer reserves the right to, and at its option may, refund the purchase price in full
satisfaction of any warranty obligations hereunder.

4.  Manufacturer shall not be liable for incidental or consequential damages and in all events
its liability hereunder shall not exceed the purchase price of the unit.
5.  MANUFACTURER DISCLAIMS ANY OTHER WARRANTY AND THIS WARRANTY IS
EXPRESSLY GIVEN IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED AND
INCLUDING BUT NOT LIMITED TO THAT OF MERCHANTABILITY, ANY WARRANTY
WHICH MAY BE IMPLIED BY LAW SHALL BE LIMITED IN TIME TO THE DURATION OF
THIS WRITTEN WARRANTY.

6.  Manufacturer neither authorizes nor assumes responsibility for any other affirmation of fact,
description or representation with respect to its products.  Manufacturer neither assumes nor
authorizes any person to assume any obligation or liability with regard to its products except as
expressly set forth herein.

Note: Some states do not allow limitations on how long an implied warranty lasts or the
exclusion or limitation of incidental or consequential damages, so the above limitations or
exclusions may not apply to you.  This warranty gives you specific legal rights which may
vary from state to state.

PAULIN PRODUCTS, Inc.

  

Sales Office: 36 South Franklin Street  •  Chagrin Falls, OH 44022  •  440-247-0828  •  FAX: 440-247-7443

 www.paulinproducts.com

Содержание Model 9

Страница 1: ...r your gaslight unless you have been thoroughly trained and are experienced in such matters If your gaslight appears to be mal functioning turn it to the OFF position and immediately contact your local dealer or the Paulin factory After installation and before use have qualified gas personnel approve your installation and check for gas leaks using a leak detector Tubing fittings gaslight valve and...

Страница 2: ...e the gaslight to malfunction Copper gas tubing Copper gas tubing must be internally tinned to meet National Gas Code Standards unless otherwise directed by local codes Nozzle All gaslights are equipped with standard propane nozzles To use gaslights at eleva tions of 4500 feet or more above sea level order High Altitude Nozzle L9 52A for propane gas or L9 61A for butane gas Note Never touch drille...

Страница 3: ... Seal and burner nose should be screwed securely into bunsen The seal must be replaced anytime the burner nose is removed after the lamp has been used Bunsen Flow of combustion air and ventilation air must not be obstructed To ensure proper air flow and gas mixture the inside of the bunsen must be clean and free of any material that may potentially accumulate such as spider webs insects etc Make a...

Страница 4: ...ubing 3 8 inch outside diameter is recommended Copper tubing must be internally tinned to meet National Fuel Gas Code unless otherwise directed by local codes Fittings If 3 8 inch copper tubing is used a 3 8 inch Flare Male Connector x 1 8 NPT Straight Fitting is required Paulin L22 12A included If Gaslight is to be connected from behind through wall a 1 8 NPT Street Elbow Male Female Paulin L22 2...

Страница 5: ...ge 4 It is easier to connect the tubing before fastening Wall Bracket assembly to wall also Wall Bracket Assembly is less likely to be bent Valve Assembly D must be straight on the Wall Bracket Nozzle N must aim into the center of the Bunsen S for proper air and gas mixture 3 Fasten Wall Bracket Assembly to wall using four mounting screws A supplied CAUTION DO NOT OVERTIGHTEN SCREWS The four Bosse...

Страница 6: ...opening so that it will fit over the ceramic burner nose and seat in lower groove of burner nose Do not tie the mantle to the Bunsen Distribute puckers in the mantle evenly around the burner nose Pull the ends of the string snugly so that mantle and string are seated securely in the burner nose groove Tie a double knot and clip off excess string 3 Replace globe 4 Mantle burn off WITH GASLIGHT VALV...

Страница 7: ......

Страница 8: ...ure to give full information including date and place of purchase full name and address 3 Manufacturer reserves the right to and at its option may refund the purchase price in full satisfaction of any warranty obligations hereunder 4 Manufacturer shall not be liable for incidental or consequential damages and in all events its liability hereunder shall not exceed the purchase price of the unit 5 M...

Отзывы: