GASLIGHT LOCATION, MOUNTING & ASSEMBLY
Read all instructions and Gaslight Warning
Tag (attached to light) before installing light.
Make sure that the gas supply is turned OFF
at the supply tank and that the gaslight valve
handle is in the “OFF” position.
Plumbing Supplies:
The following plumbing supplies are needed for installation. They are available from your
local gas dealer.
Copper Tubing:
Internally tinned copper tubing, 3/8-inch outside diameter, is recommended. Copper tubing
must be internally tinned to meet National Fuel Gas Code unless otherwise directed by local
codes.
Fittings: If 3/8-inch copper tubing is used, a 3/8-inch Flare Male Connector x 1/8 NPT
Straight Fitting is required, Paulin #L22-12A (included).
If Gaslight is to be connected from behind (through wall), a 1/8 NPT Street Elbow (Male-
Female), Paulin #L22-23A (included) must be used in addition to the Straight Fitting.
Permanent screws that attach valve assembly to wallplate
SHOULD NEVER BE LOOSENED OR REMOVED.
Removing valve assembly from wallplate WILL VOID WARRANTY.