1. Configure IP address
39
SmartNode 4900 User Manual
4 • Getting started with the SmartNode 4900 Series
Connect to the RS-232 console port
The RJ-45
Console
port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and
cable (see
figure 17
) between the SmartNode’s Console port and a PC or workstation’s RS-232 serial interface.
Activate the terminal emulation program on the PC or workstation that supports the serial interface
(e.g. HyperTerm).
Figure 17. Connecting to the RS-232 Console port
Terminal emulation program settings:
•
Asynchronous
•
9600 bps
•
No parity
•
8 bit
•
1 stop bit
•
No flow control
100-240V
(50-60 Hz)
1 AMP
UNIT EQUIPPED WITH DUAL SUPPLIES
DISCONNECT
BOTH SUPPLIES
BEFORE SERVICING
UNIT EQUIPPED WITH DUAL SUPPLIES
DISCONNECT BOTH SUPPLIES
BEFORE SERVICING
100-240V
(50-60 Hz)
1 AMP
ETH 0/0
NIC ADDRESS
00:A0:BA:00:04:10
Console
Telco Ports
50
1
Reset
Expansion
ETH 0/1
Status
Activity
Console port
Laptop PC
Model 16F-561
adapter and cable
Содержание SmartNode 4900