Patton OnSite 3088A/I Скачать руководство пользователя страница 45

Warranty Service and Returned Merchandise Authorizations (RMAs)

45

Model 3088A/I User Manual 

8 • Contacting Patton for assistance

Out-of-warranty service

Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no 
longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro-
phes may require replacement.

Returns for credit

Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 
days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or 
you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is 
not responsible for equipment returned without a Return Authorization.

Return for credit policy 

Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment. 

30 to 60 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price). 

Over 60 days: Products will be accepted for repairs only. 

RMA numbers

RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following: 

Completing a request on the RMA Request page in the 

Support

 section at 

www.patton.com

By calling 

+1 (301) 975-1007 

and speaking to a Technical Support Engineer

By sending an e-mail to 

[email protected]

All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use 
the original packing material that the device came in or pack the unit securely to avoid damage during shipping.

Shipping instructions

The RMA number should be clearly visible on the address label. Our shipping address is as follows:

Patton Electronics Company

RMA#: xxxx
7622 Rickenbacker Dr.
Gaithersburg, MD 20879-4773 USA

Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return 
shipping costs.

Содержание OnSite 3088A/I

Страница 1: ...ort patton com WWW www patton com Part Number 07M3088AI Rev A Revised March 30 2012 Important This is a Class A device and is intended for use in a light industrial environment It is not intended nor...

Страница 2: ...roduct should it fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modificat...

Страница 3: ...4 Operation 31 5 Remote console operation 35 6 Software Upgrade 39 7 Reset configuration to factory defaults 41 8 Contacting Patton for assistance 43 A Compliance information 46 B Specifications 48 C...

Страница 4: ...ternal AC universal power supply 15 External 48 VDC power supply 15 2 Configuration 16 Introduction 17 Software CLI configuration 17 Hardware DIP switch configuration 17 Configuring the DIP switches 1...

Страница 5: ...ssion 36 How to Connect 36 How to Disconnect 37 Differences in Local and Remote Control Session Behavior 38 6 Software Upgrade 39 Introduction 40 7 Reset configuration to factory defaults 41 Introduct...

Страница 6: ...n 49 Configuration 49 Power and power supply specifications 49 External AC universal power supply 50 External 48 VDC power supply 50 Transmission line 50 Line coding 50 Line rates DSL line 51 Line int...

Страница 7: ...pplication 27 5 Model 3088A I rear panel 29 6 DC Power Supply 30 7 Model 3088A I front panel 32 8 Model 3088A I Block Diagram 33 9 Local Analog Loopback diagram 33 10 Remote Digital Loopback diagram 3...

Страница 8: ...gurable parameters 17 3 Model 3088A I Series S1 DIP Switch Functions Configuration 19 4 Model 3088A I Series S3 DIP Switch Functions Test Modes and Patterns 19 5 S4 2 through S4 8 Data Rate DIP switch...

Страница 9: ...page 35 describes how to install and operate the OnSite CPE Chapter 6 on page 39 describes how to configure the OnSite CPE save the configuration reset the CPE to the factory default condition and up...

Страница 10: ...ghts The shock hazard symbol and WARNING heading indicate a potential electric shock hazard Strictly follow the warning instructions to avoid injury caused by electric shock The alert symbol and WARNI...

Страница 11: ...re rated for proper voltage current anticipated temperature flammability and mechanical serviceability WAN LAN PSTN ports connections may have hazardous voltages present regardless of whether the devi...

Страница 12: ...ood skin contact Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground To properly guard against ESD damage and shocks the wrist strap and cor...

Страница 13: ...13 Chapter 1 General information Chapter contents OnSite 3088A I overview 14 Features 14 Power input connector 15 External AC universal power supply 15 External 48 VDC power supply 15...

Страница 14: ...made with an RJ 45 jack Standard versions of Model 3088A I are powered by an 100 230 VAC Universal supply The CPE features externally accessible DIP switches loopback diagnostics SNMP HTTP remote man...

Страница 15: ...ditional specifications Input Rated voltage 36 60 VDC Rated current 0 25 A DC 3 pin locking connector 3 5 mm pitch Transient over voltage protection 100VDC at 2 ms Output Rated voltage 5 VDC 5 5W Rate...

Страница 16: ...tem reset mode 18 DIP switch settings 18 DIP switch settings 19 S4 2 through S4 8 Data Rate 20 Ethernet Management Port 23 Help Commands 24 System Configuration Commands 24 System Status Commands 24 D...

Страница 17: ...rating in DIP switch mode you cannot change any configuration settings Changing the DIP switch settings while the device is running requires the dsl start command If you attempt to modify the configur...

Страница 18: ...For basic configuration use DIP switch S1 For testing the 3088A I use DIP switch S3 To configure the rate use DIP switch S4 This figure shows the DIP switch orientation with respect to ON and OFF posi...

Страница 19: ...for data only ON All ports used for data only OFF Any port can be used for management if S1 5 is also OFF S1 5 Ethernet Port 0 Management Eth 0 is used for management only ON Ethernet Port 0 is used...

Страница 20: ...F ON ON 832 OFF OFF OFF ON ON OFF OFF 896 OFF OFF OFF ON ON OFF ON 960 OFF OFF OFF ON ON ON OFF 1024 OFF OFF OFF ON ON ON ON 1088 OFF OFF ON OFF OFF OFF OFF 1152 OFF OFF ON OFF OFF OFF ON 1216 OFF OFF...

Страница 21: ...OFF ON 3520 OFF ON ON OFF ON ON OFF 3584 OFF ON ON OFF ON ON ON 3648 OFF ON ON ON OFF OFF OFF 3712 OFF ON ON ON OFF OFF ON 3776 OFF ON ON ON OFF ON OFF 3840 OFF ON ON ON OFF ON ON 3904 OFF ON ON ON O...

Страница 22: ...OFF OFF ON ON ON ON 5184 ON OFF ON OFF OFF OFF OFF 5248 ON OFF ON OFF OFF OFF ON 5312 ON OFF ON OFF OFF ON OFF 5376 ON OFF ON OFF OFF ON ON 5440 ON OFF ON OFF ON OFF OFF 5504 ON OFF ON OFF ON OFF ON...

Страница 23: ...r Annex B The following status information is available through the command line interface Configuration Mode Whether the 3088A I is configured by DIP switches or software DSL Link State In Progress S...

Страница 24: ...nsole recognizes dsl show errcntr help Lists all the commands that start with dsl show errcntr that the console recognizes System Configuration Commands The following commands allow the user to config...

Страница 25: ...condition noise margin and test mode status DSL Clear Errcntrs Command The dsl clear errcntrs command clears the error counters Remote Console Provided that there is a DSL link to a second 3088A I a...

Страница 26: ...fm mii txpackets 0 mii rxpackets 1 efm txpackets 0 efm rxpackets 0 port 0 tx 91 port 0 rx 150 port 1 tx 0 port 1 rx 0 port 2 tx 0 port 2 rx 0 port 3 tx 0 port 3 rx 0 3088A I system show config configu...

Страница 27: ...Model 3296RC at the Central Office CO The stand alone unit at the Customer Premise CP site will automatically configure itself to the DTE rate Bandwidth Allocation defined at the Model 3296RC Other c...

Страница 28: ...Chapter 3 OnSite installation Chapter contents Installation 29 Connecting the DSL interface 29 Connecting the Ethernet interface 30 Connecting power 30 External AC universal power supply 30 DC Power...

Страница 29: ...oth units at the end of the twisted pair DSL span must be set for the same DTE rate one unit set as CO the other as CP 2 To function properly the Model 3088A I needs one twisted pair of metallic wire...

Страница 30: ...and the barrel power connector plugs into the barrel power supply jack on the 3088A I See Figure 6 Figure 6 DC Power Supply The interconnecting cables shall be acceptable for external use and shall b...

Страница 31: ...31 Chapter 4 Operation Chapter contents Introduction 32 Power up 32 LED status monitors 32 Power Green 32 DSL Green 32 Link Green 32 Activity Green 32 Test modes 33 Loopbacks 33 Patterns 34...

Страница 32: ...At startup during the POST the LED blinks once every second If the POST fails the unit does not enter normal operation and the LED blinks once every 0 4 seconds DSL Green The DSL LED glows solid while...

Страница 33: ...te end if the link is up Figure 9 Local Analog Loopback diagram The data received is looped back before going out on the DSL line Note that this loopback occurs after the pattern generator BER meter T...

Страница 34: ...pattern is started the DSL framer uses its internal 511 pattern generator for its DSL TX data instead of the data received from the serial interface Also the framer s internal BER Meter tries to detec...

Страница 35: ...apter 5 Remote console operation Chapter contents Introduction 36 Establishing a Remote Console Session 36 How to Connect 36 How to Disconnect 37 Differences in Local and Remote Control Session Behavi...

Страница 36: ...n as success if the DSL link is established 4 At the command prompt enter the command remote console 5 Wait for the message Console Remote console connection established If a DSL link is not establish...

Страница 37: ...ession How to Disconnect The remote console session ends under any of the following conditions The user enters the command logout A timeout period of 5 minutes elapses since the user has entered a com...

Страница 38: ...s able to do so whether or not the PC far end is in an active local session because the RCS has pri ority over a local console session If the PC near end establishes an RCS while the PC far end is on...

Страница 39: ...39 Chapter 6 Software Upgrade Chapter contents Introduction 40...

Страница 40: ...t to the Model 3088A I via the Ethernet management port and a Telnet session 2 Enter the system show info command to view the unit s MAC address 3 Configure a BOOTP TFTP server and enter the system up...

Страница 41: ...41 Chapter 7 Reset configuration to factory defaults Chapter contents Introduction 42...

Страница 42: ...nfiguration can be reset to factory defaults using DIP switch S1 A factory reset allows a user to recover from a forgotten password To reset to the configuration 1 Turn the Model 3088A I off 2 Turn th...

Страница 43: ...n support headquarters in the USA 44 Alternate Patton support for Europe Middle East and Africa EMEA 44 Warranty Service and Returned Merchandise Authorizations RMAs 44 Warranty coverage 44 Out of war...

Страница 44: ...253 663 5693 Alternate Patton support for Europe Middle East and Africa EMEA Online support available at www patton inalp com E mail support e mail sent to support patton inalp com will be answered w...

Страница 45: ...e issued upon receipt and inspection of the equipment 30 to 60 days We will add a 20 restocking charge crediting your account with 80 of the purchase price Over 60 days Products will be accepted for r...

Страница 46: ...46 Appendix A Compliance information Chapter contents Compliance 47 EMC 47 Safety 47 Radio and TV Interference FCC Part 15 47 CE Declaration of Conformity 47 Authorized European Representative 47...

Страница 47: ...device does cause interference to radio or television reception which can be determined by disconnecting the unit the user is encouraged to try to correct the interference by one or more of the follo...

Страница 48: ...een 49 DSL Green 49 Link Green 49 Activity Green 49 Configuration 49 Power and power supply specifications 49 External AC universal power supply 50 External 48 VDC power supply 50 Transmission line 50...

Страница 49: ...is training it blinks once every second Link Green The Link LED shows that there is an active physical network connection to the Console or an Ethernet device Activity Green The Activity LED shows th...

Страница 50: ...Transmission line Single Twisted Pair Line coding TC PAM Trellis Coded Pulse Amplitude Modulation The external AC adaptor shall be a listed limited power source that incorporates a disconnect device a...

Страница 51: ...ion G SHDSL physical connection RJ 45 2 wire polarity insensitive pins 4 and 5 Environment Operating temp 32 122 F 0 50 C Humidity 5 95 non condensing Altitude 0 15 000 feet 0 4 600 meters Third party...

Страница 52: ...52 Appendix C Factory default values Chapter contents Factory default values for software configurable parameters 53...

Страница 53: ...for software configurable parameters Note The default management IP address is 192 168 200 1 Note The default logout timer value is set for 300 seconds 5 minutes Table 6 3088A I Parameter Default val...

Страница 54: ...54 Appendix D Factory replacement parts and accessories Chapter contents Factory replacement parts and accessories 55...

Страница 55: ...acement parts and accessories Factory replacement parts and accessories Power Supplies PS 03671H1 00 100 240VAC 12V DC 2A Wall mount power adapter Power Adapters 12 130 European replacement plug 12 12...

Страница 56: ...56 Appendix E Interface pinouts Chapter contents Line port 57 Ethernet port 57...

Страница 57: ...Line port RJ 45 connector Ethernet port Note Pins not listed are not used Pin Signal 1 No connection 2 No connection 3 No connection 4 Tip 5 Ring 6 No connection 7 No connection 8 No connection Table...