Introduction
19
Model 3088A/I User Manual
2 • Configuration
DIP switch settings
The following tables provide an overview of the OnSite DIP switch functions.
Table 3. Model 3088A/I Series - S1 DIP-Switch Functions (Configuration)
Position
Function
Settings
S1-1
Software Reset
Software Reset
S1-2
Reserved
Reserved
S1-3
S1-4
No Management Port
(All Ethernet ports are used for data only)
ON - All ports used for data only
OFF - Any port can be used for management
(if S1-5 is also OFF)
S1-5
Ethernet Port 0 Management
(
Eth 0
is used for management only)
ON - Ethernet Port 0 is used for management
OFF - Any port can be used for management
(if S1-4 is also OFF)
S1-6
Annex
ON - Annex B
OFF - Annex A
S1-7
Reserved
Reserved
S1-8
DSL Mode
ON - CO
OFF - CPE
Table 4. Model 3088A/I Series - S3 DIP-Switch Functions (Test Modes and Patterns)
Position
Function
S3-1
Reserved
S3-2
S3-3
S3-4
S3-5
511e Pattern
S3-6
511 Pattern
S3-7
Test Mode Remote
S3-8
Test Mode Local