Model 3202 rear panel
21
Model 3202 Getting Started Guide
1 • General information
Reset button
•
To restart the unit with the current startup configuration—Press for less than 1 second and release the
Reset
button. The Model 3202 will restart with the current startup configuration.
•
To restart the unit with factory default configuration—Press the
Reset
button for 5 seconds until the Power
LED starts blinking. The unit will restart with factory default configuration.
•
To restart the unit in bootloader mode (to be used only by trained RocketLink technicians)—Start with the
unit powered off. Press and hold the
Reset
button while applying power to the unit. Release the
Reset
button
when the
Power
LED starts blinking so the unit will enter bootloader mode.
Ground terminal
The marked lug or terminal should be connected to the building protective earth bus.The func-
tion of protective earth does not serve the purpose of providing protection against electrical shock,
but instead enhances surge suppression on the DSL lines for installations where suitable bonding
facilities exist.The connector type is M3 machine screw.