OnSite System Installation
36
OnSite Series Getting Started Guide
3 • Installation Overview
Figure 13. Wiring the OS-10 System for DC Power
1.
Choose an available circuit from a DC power source and identify both the positive and negative leads for
this circuit.
Note
The DC power source may be a DC circuit breaker or an AC-to-DC
power rectifier.
2.
Remove power from this circuit.
Note
To ensure that power is removed from the DC circuit, locate the cir-
cuit breaker for the DC circuit, switch the circuit breaker to the OFF
position, and tape the circuit-breaker switch in the OFF position.
3.
Strip the DC input wires that will connect the circuit to the DC power terminal block on the OS-10 sys-
tem to the appropriate length.
4.
Connect the positive lead of this circuit to ground. See wiring 1-A in
Figure 13
.
Note
As an option, you may choose another common grounding point
other than the one shown in
Figure 13
. The choice depends on the
grounding practice for your particular location.
Figure 13
shows the
grounding point colocated with the DC circuit for “A” power.
•Do not touch the circuit with your hands or with any other instrument until
you make sure that there is no power present on the circuit.
•Make sure that power is removed from the DC circuit that will supply power
to the OS-10 system before performing any of the following procedures.
WARNING
Содержание OnSite 07MOS10xx-GS
Страница 14: ...14 Chapter 1 Product Overview Chapter contents Introduction 15 OnSite Platforms 15...
Страница 18: ...18 Chapter 2 Application Overview Chapter contents OS1052 Application 19 OS1063 Application 21...
Страница 63: ...63 Appendix C Terms and Acronyms Chapter contents Abbreviations 64...