Alarm System Overview window
51
Models 2616RC, 3096RC & 3196RC Admin Reference Guide
4 • Alarms
Figure 14. Sample alarm indications
•
Management web page indication—The
Alarms
section (see
figure 14
) of the
Alarm System
Overview
win-
dow (see
figure 13
on page 50) uses color-coded highlighting to indicate which alarms are active and the
severity levels of active alarms.
-
RED
: indicates that one or more
CRITICAL
(severity 4) alarms are active. When active,
critical
alarm
notifications also appear as red highlighting on the
HOME window
(see
figure 4
on page 38) and as a
flashing red star (see
figure 137
on page 252) on the
System Status
window (see
figure 136
on page 252).
-
ORANGE
: indicates that one or more
MAJOR
(severity 5) alarms are active. When active,
major
alarm notifi-
cations also appear as orange highlighting on the
HOME window
(see
figure 4
on page 38) and as an orange
exclamation mark (see
figure 137
on page 252) on the
System Status
window (see
figure 136
on page 252).
-
YELLOW
: indicates that one or more
MINOR
(severity 6) alarms are active. When active,
minor
alarm
notifications also appear as yellow highlighting on the
HOME window
(see
figure 4
on page 38) and as a
yellow triangle (see
figure 137
on page 252) on the
System Status
window (see
figure 136
on page 252).
-
BLUE
: indicates that one or more
INFORMATIONAL
(severity 7) alarms are active. Being informa-
tional in nature, these alarms only appear on the
Alarm System
main window to indicate that an event has
occurred, they do not generate alarm indications anywhere else.
•
External host indication—For external notification, the T-DAC can be configured to send a Syslog event
notification or an SNMP trap message (or both) to an external alarms management host. To configure the
T-DAC to send SNMP traps or Syslog messages in response to alarm conditions, click on the
Modify
Parameters
hyperlink (see
figure 14
on page 51) to open the
Alarm System Configuration—Alarm Response
Outputs
window (refer to section
“Alarm System Configuration window”
on page 52).
In addition to viewing current alarm status, you can force the T-DAC to generate an alarm as a test by clicking
on the
Generate Alarm
button for the desired alarm. Click on the
Clear Alarm
button to clear the alarm
when the test is concluded.